![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1566461.1 : T10000x/9x40 - How to Change the Physical Addressing Scheme From Soft to Hard Addressing
Changing the addressing scheme of T10000x and 9x40 from Soft to Hard addressing to support Arbitrated Loop physical addressing (ALPA). In this Document
Created from <SR 3-7412884784> Applies to:Sun StorageTek 9840A Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek 9840 Tape Drive - Version Not Applicable to Not Applicable [Release N/A] Sun StorageTek T10000 Tape Drive - Version Not Applicable to Not Applicable [Release N/A] Sun StorageTek T10000A Tape Drive - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. 9x40 T10000x GoalChanging the addressing scheme of T10000x and 9x40 from Soft to Hard addressing to support Arbitrated Loop physical addressing (ALPA). SolutionCertain applications and device configurations (specifically Arbitrated loop (ALPA)) require drives to be predefined with a specific physical address (known as 'Hard' addressing). This is not the default for T10000 or 9x40 which normally, in an interface fabric context, have their addresses automatically assigned in ascending order on loop initialisation. Drives shipped from manufacturing are preset to accept this (SOFT PA HI). Should hard addressing be required please use either of the following methods. It is strongly advised to follow the guidance set out in the relevent documentation for each of these methods) :- Using the Virtual Operator Panel Software (VOP) with the drive offline :- Select the 'Configure' Menu (or CNTL+C) Select 'Drive Data' (or CNTL+D) to show the 'Configure Drive Parameters' dialog. Select the 'Hard Assigned Physical address' for the correct Interface Pa or Pb (Port A or Port B) to 'Yes' Change the Arbitrated loop Physical Address as desired. Press the 'Configure' button or (ALT+C). n.b.This will IPL the drive. Full VOP usage details are given in the Storagetek VOP User's Guide E37053-01. VOP is downloadable from MOS.
Using the 9x40 drive operator panel with the drive offline:- With the menu at ' *' Press Select Select the correct port and disable it. Select 'Chng CFG? Keep Pressing 'Menu' until 'CFG prtx' is displayed. Press Select Select 'Hard PA Y' Set 'PA=xx ,yyy' by pressing the select button Once set, keep pressing Menu until 'Save/IPL?' is displayed. Drive will IPL. For full details see the 9x40 Service Reference Manual P/N 95740 (restricted)
T10000x drive menus are operated in the same manner to 9x40 with minor differences. Full details in the Storagetek T10000 Service Manual P/N 96175 (restricted)
References<NOTE:1321007.1> - Tape - How to Download StorageTek Software (SLC, VOP, ACSLS) via Oracle Software Delivery Cloud (E-Delivery)<NOTE:1009827.1> - L700/L180 - 9840FC Hard Addressing & Installation Configuration Attachments This solution has no attachment |
||||||||||||||||
|