Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1563524.1
Update Date:2018-04-13
Keywords:

Solution Type  Technical Instruction Sure

Solution  1563524.1 :   Unable To Configure Network Management Port In ILOM  


Related Items
  • SPARC T5-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Interfaces
  •  




In this Document
Goal
Solution


Created from <SR 3-7415763501>

Applies to:

SPARC T5-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
It is always good practice to ensure the IP addresses selected are falling in right group of Subnet address depending on Subnet mask.

Here in above example, the gateway ip address and ip address of net mgmt port intended to configure for given subnet mask, were from different Subnets, and hence ILOM refused to configure network IP addresses.

Goal

Problem statement:
Not able to set IP address to net management port of SP.

i.e.
-> set /SP/network commitpending=true
set: Unable to configure network


Given:
============================
  pendingipaddress = 192.168.183.191
  pendingipdiscovery = static
  pendingipgateway = 192.168.183.206
  pendingipnetmask = 255.255.255.240
============================
 

Solution

For the 192.168.183.206 gateway network address, with subnet mask 255.255.255.240 (/28), the valid range of addresses are from 192.168.183.193 to 192.168.183.206.  A total of 14 IP addresses are available, with the network address 192.168.183.192/28, and the broadcast address 192.168.183.207.

Suggestion was to try 192.168.183.193 instead of 192.168.183.191 to resolve the issue.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.