Solution Type Technical Instruction Sure Solution 1563524.1 : Unable To Configure Network Management Port In ILOM
In this Document
Created from <SR 3-7415763501> Applies to:SPARC T5-2 - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. It is always good practice to ensure the IP addresses selected are falling in right group of Subnet address depending on Subnet mask. Here in above example, the gateway ip address and ip address of net mgmt port intended to configure for given subnet mask, were from different Subnets, and hence ILOM refused to configure network IP addresses. GoalProblem statement: SolutionFor the 192.168.183.206 gateway network address, with subnet mask 255.255.255.240 (/28), the valid range of addresses are from 192.168.183.193 to 192.168.183.206. A total of 14 IP addresses are available, with the network address 192.168.183.192/28, and the broadcast address 192.168.183.207. Attachments This solution has no attachment |
||||||||||||||
|