Goal

How to reset ILOM (3.x and later) root account password using serial management port on a Sun Blade 6000 CMM (Chassis Management Module)

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems

Solution

1) Connect via a serial console to the CMM module and open terminal window


2) Press <Enter> and when asked for login username type: default


3) Press locator button on CMM module


4) When asked for password type: defaultpassword


5) Reset root password with the following command:

 

  -> set /CMM/users/root password
  Enter new password again: ********
  New password was successfully set for user /CMM/users/root

 


Info available in ILOM documentation on http://docs.oracle.com/
- ILOM 3.2 - https://docs.oracle.com/cd/E37444_01/html/E37446/z400203c1534691.html
- ILOM 3.1 - http://docs.oracle.com/cd/E24707_01/html/E24528/z400203c1534691.html
- ILOM 3.0 - http://docs.oracle.com/cd/E19860-01/E21549/z40012541396645.html