In this Document
Goal
Solution


Created from <SR 3-7071833491>

Applies to:

Sun Fire X4100 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

How to set the iLOM date and time from the iLOM CLI (Command Line Interface) console

Solution

  Set the iLOM date using the following command:

-> set /SP/clock datetime=MMDDhhmmYYYY.ss

 
(Change MMDDhhmmYYYY.ss  with current date & time ).

If an NTP server is  enabled, disable the server first then update the date and time using this command.

You can disable NTP server synchronisation by running following command, which disables the NTP service:

-> set /SP/clock/usentpserver=disabled

 
Once the NTP service is disabled you can set the ILOM date and time.