Solution Type Technical Instruction Sure Solution 1557937.1 : Fujitsu M10-4S - Using Diagxbu to Find Loose or Mis-Cabled Fiber Cable Building Blocks
In this Document
Applies to:Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalIn a M10-4s multiple building block configuration, all the fiber cables can make troubleshooting them very complex. SolutionIf the LSB is allocated to a ppar the associated ppar must be powered off. On the main XSCFU, use the diagxbu command to find loose, missing, or crossed cables. Please see the examples below. TEST #1 XSCF> diagxbu -b 0 -t 1
XBU diagnosis is about to start, Continue?[y|n] :y Power on sequence started. [7200sec] 0..... 30..... 60..... 90.....120....end XBU diagnosis started. [7200sec] 0..... 30..... 60..... 90.....120.....150.....180.....210.....240.....\ 270.....300.....330.....360.....390.....420.....450.....480.....510...../ 540.....570.....600.....630.....660.....690.....720.....750.....780.....- 810.....840.....870.....900.....930.....960.....990.....1020.....1050.....- 1080....end completed. Power off sequence started. [1200sec] 0..... 30..... 60..... 90.....120.....150.end completed. *Note* Please confirm the error of XBU by "showlogs error". In addition, please confirm the degraded of XBU by "showstatus". XSCF> NOTE: It took about 16 minutes for the test to run normally with no errors on my lab 2 BB M10-4s configuration
TEST #2 XSCF> diagxbu -b 0 -t 1
XBU diagnosis is about to start, Continue?[y|n] :y Power on sequence started. [7200sec] 0..... 30..... 60..... 90.....120.....150end XBU diagnosis started. [7200sec] 0..... 30..... 60..... 90.....120end A Hardware error occurred by XBU diagnosis. Power off sequence started. [1200sec] 0..... 30..... 60..... 90.end completed. A hardware error occurred. Please check the error log for details. *Note* Please confirm the error of XBU by "showlogs error". In addition, please confirm the degraded of XBU by "showstatus". XSCF> XSCF> showlogs -r -M error Date: May 29 12:03:38 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 12:03:34.409 PDT 2013 FRU: /BB#1/XBU#0/CBL#1L Msg: Cable connection test failure Date: May 29 12:03:30 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 12:03:25.288 PDT 2013 FRU: /BB#1/XBU#0/CBL#1L Msg: Cable connection test failure
NOTE: It took about 8 minutes for the test to find the error and then exit on my lab 2 BB M10-4s configuration
XSCF> diagxbu -b 0 -t 1
XBU diagnosis is about to start, Continue?[y|n] :y Power on sequence started. [7200sec] 0..... 30..... 60..... 90.....120.....150end XBU diagnosis started. [7200sec] 0..... 30..... 60..... 90.....120end A Hardware error occurred by XBU diagnosis. Power off sequence started. [1200sec] 0..... 30..... 60..... 90....end completed. A hardware error occurred. Please check the error log for details. *Note* Please confirm the error of XBU by "showlogs error". In addition, please confirm the degraded of XBU by "showstatus". XSCF> showlogs -r -M error Date: May 29 10:57:30 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 10:57:19.439 PDT 2013 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure Date: May 29 10:57:24 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 10:57:19.073 PDT 2013 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure
XSCF> diagxbu -b 0 -t 1
XSCF> diagxbu -b 0 -t 1
XBU diagnosis is about to start, Continue?[y|n] :y Power on sequence started. [7200sec] 0..... 30..... 60..... 90.....120.....end XBU diagnosis started. [7200sec] 0..... 30..... 60..... 90.....120.end A Hardware error occurred by XBU diagnosis. Power off sequence started. [1200sec] 0..... 30..... 60..... 90..end completed. A hardware error occurred. Please check the error log for details. *Note* Please confirm the error of XBU by "showlogs error". In addition, please confirm the degraded of XBU by "showstatus". XSCF> showlogs -r -M error Date: May 29 15:57:22 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 15:57:22.583 PDT 2013 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure Date: May 29 15:57:21 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 15:57:21.576 PDT 2013 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure Date: May 29 15:56:59 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 15:56:49.292 PDT 2013 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure Date: May 29 15:56:53 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 15:56:48.679 PDT 2013 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure
Reversed(crossed) 2 cables on BB#0 (XBU#0 0L Black and XBU#1 0L Pink) XSCF> diagxbu -b 0 -t 1
XBU diagnosis is about to start, Continue?[y|n] :y Power on sequence started. [7200sec] 0..... 30..... 60..... 90.....120.....end XBU diagnosis started. [7200sec] 0..... 30..... 60..... 90.....120.end A Hardware error occurred by XBU diagnosis. Power off sequence started. [1200sec] 0..... 30..... 60..... 90..end completed. A hardware error occurred. Please check the error log for details. *Note* Please confirm the error of XBU by "showlogs error". In addition, please confirm the degraded of XBU by "showstatus". XSCF> XSCF> XSCF> showlogs -r -M error Date: May 29 16:11:00 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 16:10:59.936 PDT 2013 FRU: /BB#0/XBU#1/CBL#0L Msg: Cable connection test failure Date: May 29 16:10:59 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 16:10:59.429 PDT 2013 FRU: /BB#0/XBU#1/CBL#0L Msg: Cable connection test failure Date: May 29 16:10:44 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 16:10:33.757 PDT 2013 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure Date: May 29 16:10:39 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 16:10:27.651 PDT 2013 FRU: /BB#0/XBU#1/CBL#0L Msg: Cable connection test failure Date: May 29 16:10:39 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 16:10:27.404 PDT 2013 FRU: /BB#0/XBU#0/CBL#0L Msg: Cable connection test failure Date: May 29 16:10:31 PDT 2013 Code: 10000008-007cff0000ff0000ff-019204310000000000000000 Status: Information Occurred: May 29 16:10:26.494 PDT 2013 FRU: /BB#0/XBU#1/CBL#0L Msg: Cable connection test failure Attachments This solution has no attachment |
||||||||||||||
|