Solution Type  Technical Instruction Sure

Solution  1552089.1 :   How to reset F20 ESM UPTIME on x4540  


Related Items
  • Sun Fire X4540 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Server>SN-x64: AMD-STOR-SERVER
  •  




In this Document
Goal
Solution
References


Created from <SR 3-6804559581>

Applies to:

Sun Fire X4540 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to reset F20 ESM UPTIME on x4540

Solution

After replaced F20 ESM (Energy Storage Module), we need reset ESM UPTIME.

The SunFire x4540 range of platforms do not included the ILOM "faultmgmt" function. So we need follow the below procedure to reset UPTIME.

Before ESM replacement:

/SYS/MB/PCIE0/F20CARD/UPTIME
Properties:
type = Power Unit
ipmi_name = PCIE0/F20C/UT
class = Threshold Sensor
value = 17900.000 Hours <------here
upper_nonrecov_threshold = 17500.000 Hours

Reset UPTIME after ESM replacement:

-> cd /SYS/MB/PCIE0/F20CARD/UPTIME
/SYS/MB/PCIE0/F20CARD/UPTIME

-> reset
Are you sure you want to reset /SYS/MB/PCIE0/F20CARD/UPTIME (y/n)? y
Performing reset on /SYS/MB/PCIE0/F20CARD/UPTIME

 Resulting output:

-> show

/SYS/MB/PCIE0/F20CARD/UPTIME
   Targets:

   Properties:
        type = Power Unit
        ipmi_name = PCIE0/F20C/UT
        class = Threshold Sensor
        value = 0.000 Hours<------here
        upper_nonrecov_threshold = 17500.000 Hours

 

References

<NOTE:1327000.1> - Sun Flash Accelerator F20 Energy Storage Module (ESM) Lifespan.
<NOTE:1505691.1> - Unable To Reset Flash F20 Accelerator ESM UPTIME