![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1552089.1 : How to reset F20 ESM UPTIME on x4540
In this Document
Created from <SR 3-6804559581> Applies to:Sun Fire X4540 Server - Version Not Applicable and laterInformation in this document applies to any platform. GoalHow to reset F20 ESM UPTIME on x4540 SolutionAfter replaced F20 ESM (Energy Storage Module), we need reset ESM UPTIME. /SYS/MB/PCIE0/F20CARD/UPTIME
Properties: type = Power Unit ipmi_name = PCIE0/F20C/UT class = Threshold Sensor value = 17900.000 Hours <------here upper_nonrecov_threshold = 17500.000 Hours Reset UPTIME after ESM replacement: -> cd /SYS/MB/PCIE0/F20CARD/UPTIME
/SYS/MB/PCIE0/F20CARD/UPTIME -> reset Are you sure you want to reset /SYS/MB/PCIE0/F20CARD/UPTIME (y/n)? y Performing reset on /SYS/MB/PCIE0/F20CARD/UPTIME Resulting output: -> show
/SYS/MB/PCIE0/F20CARD/UPTIME Targets: Properties: type = Power Unit ipmi_name = PCIE0/F20C/UT class = Threshold Sensor value = 0.000 Hours<------here upper_nonrecov_threshold = 17500.000 Hours
References<NOTE:1327000.1> - Sun Flash Accelerator F20 Energy Storage Module (ESM) Lifespan.<NOTE:1505691.1> - Unable To Reset Flash F20 Accelerator ESM UPTIME Attachments This solution has no attachment |
||||||||||||||||
|