Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1547798.1
Update Date:2016-01-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1547798.1 :   Mx-32 How to replace a Faulty Internal Link to Front LED Panel Cable  


Related Items
  • SPARC M5-32
  •  
  • SPARC M6-32
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution
 Remove the Internal Link Cable for the Front LED Panel
 Install the Internal Link Cable for the Front LED Panel
References


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

SPARC M5-32 - Version All Versions and later
SPARC M6-32 - Version All Versions and later
Oracle SuperCluster M6-32 Hardware - Version All Versions and later
Information in this document applies to any platform.

Goal

CAP PROBLEM OVERVIEW: Mx-32 How to replace a Faulty Internal Link to Front LED Panel Cable


To report errors or request improvements on this procedure, please go to My Oracle Support, and  put a comment on Doc ID: 1547798.1 .


 

ESD Caution:
  • Circuit boards and drives contain electronic components that are  extremely sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work environment can destroy the components located on these boards. Do not touch the components along their connector edges.
  • Use a Antistatic Wrist strap. Attach one end of the strap to your wrist and the other end to the chassis, depending on what type of strap you use, with the adhesive end or the metal plug.
  • Use an Antistatic Mat. Place ESD-sensitive components such as motherboards, memory, and other PCBs on an antistatic mat.

 

Contamination Caution:

  • Dust particles of packaging material are number one cause of datacenter contamination. Make sure to remove all packaging material, up to the ESD safe
  • packaging material, while still being outside the datacenter.

 

Caution – Danger of electrocution: AC circuits in the server share current. Remove all sources of AC current from the server.

 

 

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED: Mx-32 Product Training/Experience

TASK COMPLEXITY: 4

TIME ESTIMATE: 300 minutes

COLD Replacement

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?

Physical Domains must be shut down. Server must be powered off. 

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

 

Remove the Internal Link Cable for the Front LED Panel

1. Halt and power down the server.

-> stop /System

Caution – Danger of electrocution: AC circuits in the server share current. Remove all sources of AC current from the server.

Remove AC Power from the server.

2. Remove the front filler panel

M5-32 How to Service the Front Filler Panel Assembly

3. Remove the upper fan cage.

M5-32 How to Replace a Faulty Upper Fan Cage Assembly

4. Remove the scalability card cage.

M5-32 How to Replace a Faulty Scalability Card Cage

5. Remove the lower fan cage.

M5-32 How to Replace a Faulty Lower Fan Cage Assembly

6. Disconnect the lower end of the cable from the bracket.

The connector plugs into the bracket without screws. If necessary, disconnect the bracket from the chassis. Two T20 Torx screws hold the bracket to the chassis.              This bracket holds three cable connectors.
The cable is included in a group of cables that are routed up the side of the server.
Three long brackets hold the cables in place.

7. Remove the cable brackets that hold cables to the side of the cabinet

a. Remove the T20 Torx screw from the end of a bracket.
b. Pull the bracket out and set it aside.
c. Repeat these steps for the remaining brackets.

8. Disconnect the upper end of the cable.

The connector plugs into the bracket without screws. If necessary, disconnect the bracket from the chassis. Two T20 Torx screws hold the bracket to the chassis.

9. Install the new cable.

 

Install the Internal Link Cable for the Front LED Panel

1. Install the upper end of the cable in the bracket.

2. Route the cable down the side of the server.

3. Install the lower end of the cable in the socket bracket.

The connector plugs into the bracket without screws. If necessary, disconnect the bracket from the chassis. Two T20 Torx screws hold the bracket to the chassis. This
bracket holds three cable connectors

4. Install three cable brackets to hold the cables to the side of the cabinet.

5. Reinstall the lower fan cage assembly.

M5-32 How to Replace a Faulty Lower Fan Cage Assembly

6. Reinstall  the scalability card cage.

M5-32 How to Replace a Faulty Scalability Card Cage

7. Install the upper fan cage.

M5-32 How to Replace a Faulty Upper Fan Cage Assembly 

8. Install the front filler panel.

M5-32 How to Service the Front Filler Panel Assembly

9. Restart the server.

a) Reconnect AC Power to server

b) Momentarily press the On/Standby button on the front LED panel.

10. Return the replaced component to Oracle.

Place plastic cover(s) on the connectors of the component. Also return any extra covers that were included with the replacement component.

 

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.

 

======================== Other info =====================

REFERENCE INFORMATION:  Service Manual: https://www.oracle.com/technetwork/documentation/oracle-sparc-ent-servers-189996.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback