![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1546667.1 : SL24/SL48 - How to Upgrade Firmware on a Drive(s) in a SL24/48
How to upgrade firmware on a SL24/48 Tape drive(s) In this Document
Applies to:Sun StorageTek SL48 Tape Library - Version All Versions to All Versions [Release All Releases]Sun StorageTek SL24 Tape Autoloader - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. Steps for the customer to update the firmware on the SL24/48 Tape drive(s). GoalHow to upgrade the firmware / Microcode on the drive. SolutionThe following documents provided instructions on how to update the Library code: Document : 1372161.1 - How to Upgrade Firmware in SL24 Library
Document : 1372168.1 - How to Upgrade Firmware in SL48 Library
Please use MOS Document 1539632.1 to locate the code(s).
The process for the drive(s) code is as follows Note: please offline the SL24/48 from the backup software before this is done and stop all jobs.
Note: a stop and re-start of the backup application may also be needed.
REFERENCE INFORMATION: http://docs.oracle.com/cd/E25510_01/en/875-4225-12/875-4225-12.pdf
To discuss any of this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community, Oracle Tape Hardware
References<NOTE:1372161.1> - How to Upgrade Firmware in SL24 Library:ATR:1372161.1:2<NOTE:1539632.1> - How To Download Tape Drive, Library Firmware and Installation Tools from My Oracle Support <NOTE:1372168.1> - How to Upgrade Firmware in SL48 Library:ATR:1372168.1:2 Attachments This solution has no attachment |
||||||||||||||||
|