Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1546547.1
Update Date:2017-05-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1546547.1 :   IBM LTO - Process to Upgrade Belisarius Microcode On IBM LTO Drive  


Related Items
  • IBM LTO5 Tape Drive
  •  
  • IBM LTO4 Tape Drive
  •  
  • IBM LTO6 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Goal
Solution


Applies to:

IBM LTO4 Tape Drive - Version All Versions and later
IBM LTO5 Tape Drive - Version All Versions and later
IBM LTO6 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Belisarius firmware upgrade
Bel LTO Code

Goal

Process to Upgrade Belisarius Microcode On IBM LTO Drive

Solution

 

Download firmware from MOS Patches and Updates. (current patch id 145727-03 for Belisarious version 2.38.24, released on Dec/3/2012)

Use Customer or CSE version of VOP (Customer version is available on edelivery.oracle.com)

Connect to drive using IP address
Select "Service Drive" tab
Select "Load Firmware"
Select the belisarious firmware file that was downloaded from MOS

*see picture attached.

 

** Note: For LTO5 and LTO6, using latest version of VOP. An option is available to update drive firmware, as well as Belisarious firmware. But for LTO4 this option will not work.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback