SL8500 - Is the HBZ Card Imprinted With Serial Number When it is Installed in the Library?
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Goal
Is the HBZ imprinted with serial number when it's installed in the library?
Solution
The HBZ module for the CAP/SSD/Elevator is not permanently imprinted with the serial number and can be freely used in any machine and swapped as required during troubleshooting. In addition, even cards like the HBCR that are imprinted are only transient anyway. It will take whatever the serial number is of the HBK card. In other words, you can swap the card between machines. However, in the case of the HBCR, you need to be aware of installed microcode type and version as that does stay with the swapped card and can impact the receiving machine.