![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1545807.1 : SL3000/SL8500 - How to Reboot the Operator Panel on the Front of the Library via SLConsole (SLC)
In this Document
Created from <SR 3-7068720151> Applies to:Sun StorageTek SL3000 Modular Library System - Version All Versions and laterSun StorageTek SL8500 Modular Library System - Version All Versions and later Information in this document applies to any platform. GoalHow to remotely reboot the Front Panel of the Library (via SLConsole) after getting errors with connection and refreshing. SLConsole at SL8500 Cannot Be Refreshed - Get Error Message Of "no Connection" SolutionIf you have remote connection through SLConsole, you can follow the process: Tools--> Diagnostics--> Activate Code--> Selected the Target "SLConsole" and press Activate on the latest code. This will reboot the Operator Panel on the Front of the Library showing this message on the "Activate Console": Activation started
References<NOTE:1015771.1> - SL8500 - Procedure to Reset and Calibrate Operator PanelAttachments This solution has no attachment |
||||||||||||||||
|