Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1541132.1
Update Date:2017-12-13
Keywords:

Solution Type  Technical Instruction Sure

Solution  1541132.1 :   How To Reset The SB6000/SB6048 Chassis Monitoring Module (CMM) from a Blade  


Related Items
  • Sun Blade 6000 System
  •  
  • Sun Blade 6048 System
  •  
  • Sun Netra 6000 System
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: SB60xx
  •  
  • _KM>Content>Hints and Tips
  •  




In this Document
Goal
Fix


Applies to:

Sun Blade 6000 System - Version All Versions to All Versions [Release All Releases]
Sun Netra 6000 System - Version All Versions to All Versions [Release All Releases]
Sun Blade 6048 System - Version All Versions to All Versions [Release All Releases]
Sun SPARC Sun OS

Goal

Resetting the CMM of a SUN BLADE 6000/6048 MODULAR SYSTEM without access
via SSH or Web, you can do it through one of the blade(s) in the chassis using ipmitool. 

Fix


If the CMM is not accessible due to the maximum number of sessions
has been exhausted:

1) # ssh root@CMM-net-mgt
Password:
shell: Maximum number of sessions exhausted

Connection to CMM-net-mgt closed.
#

Log into a blade in the chassis:

2) root@blade1 # ipmitool -H CMM-net-mgt -U root bmc reset cold
Password:
Sent cold reset command to MC
root@blade1 #

and after that you can log into the CMM without problems

3) # ssh root@CMM-net-mgt
Password:

Sun(TM) Integrated Lights Out Manager

Version 3.0.6.11 r47352

Copyright 2009 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.

Warning: password is set to factory default.

->