M5-32 How to Repair a Faulty System Bus Bar

In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

SPARC M5-32 - Version All Versions and later
SPARC M6-32 - Version All Versions and later
Oracle SuperCluster M6-32 Hardware - Version All Versions and later
Information in this document applies to any platform.
The System Bus Bar is a cold-service component that can only be serviced by authorized service personnel.

Goal

CAP PROBLEM OVERVIEW: Mx-32 - System Bus Bar


To report errors or request improvements on this procedure, please go to My Oracle Support, and put a comment on Doc ID: 1541029.1


*************************************************************************
Note: Until Further notice all Mx-32 Parts must be submitted through
the CPAS process. See this link for more information about the CPAS process:
https://stbeehive.oracle.com/teamcollab/overview/CPAS
*************************************************************************  

ESD Caution:
  • Circuit boards and drives contain electronic components that are  extremely sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work environment can destroy the components located on these boards. Do not touch the components along their connector edges.
  • Use a Antistatic Wrist strap. Attach one end of the strap to your wrist and the other end to the chassis, depending on what type of strap you use, with the adhesive end or the metal plug.
  • Use an Antistatic Mat. Place ESD-sensitive components such as motherboards, memory, and other PCBs on an antistatic mat.

 

Contamination Caution:
  • Dust particles of packaging material are number one cause of datacenter contamination. Make sure to remove all packaging material, up to the ESD safe packaging material, while still being outside the datacenter.

 

NOTICE:  The component specified for replacement in this action plan requires a Genie Lift.  The lift is required not only for the safety of the servicing engineer, but also for the successful implementation of the replacement procedure.  Any of the following parts may be ordered to satisfy the Genie Lift requirement:

370-4286 Genie Lift w/straddle base
371-4170 Genie Lift w/Cntr-weight Base Adj
370-6889 Genie Lift w/counter-weight base
370-6888 Genie Lift w/standard base

Depending on the region/country, the order lead-time for the Genie Lift may be longer than other parts.

DO NOT ATTEMPT THE REPLACEMENT PROCEDURE WITHOUT THE REQUIRED GENIE LIFT.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED: Mx-32 Product Training/Experience

TASK COMPLEXITY: 4

TIME ESTIMATE: 180 minutes COLD replacement

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Physical Domains must be shut down. Server must be powered off. 

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Caution – The repair of a System Bus Bar requires the removal of the Power System Cage. The empty power system cage weighs 207 lbs (94kg).  At least two people and a mechanical lifting device are required for the procedure.  Complete the 'Servicing Bus Bars' procedure outlined in the M5-32 Service Manual to replace the failed component.

 