![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1536223.1 : Pillar Axiom: How to Configure the IP address on a new Axiom AX600 version R5
In this Document
Applies to:Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalHow to configure IP address on a new Pillar Axiom install FixAfter you have installed the Pillar Axiom Storage Services Manager software package on a client workstation, you can run the application to access a Pillar Axiom system.
To login to the GUI application, use one of the following options: ● For a newly installed Pillar Axiom system in which the Pilot IP address has not been changed, use an address of 10.0.0.2, which was set at the factory. Typically, this address is what you also used to download the GUI application. Alternatively, if you configured the IP address to a DNS host name, you can use that host name to log into the Pillar Axiom system.
Tip: If you forget the Primary system administrator password, you can reset it using either of these two methods: ● Use a Type 1 Administrator account, if one exists, to reset the password. A support administrator cannot reset the Primary system administrator password.
After logging in to the Pillar Axiom system, you can perform administrator tasks. ● 5 active sessions for each administrator account Note: The default time-out period is 20 minutes. When a session is inactive for more than the time-out period, the system terminates that session.
Attachments This solution has no attachment |
||||||||||||||||||||||
|