Goal

 How to configure IP address on a new Pillar Axiom install

Fix

After you have installed the Pillar Axiom Storage Services Manager software package on a client workstation, you can run the application to access a Pillar Axiom system.
The first time that you use the Primary administrator account to log in to the graphical user interface (GUI), use the following default values:


Default login values

Field

Default Value

Pilot IP address

10.0.0.2

Login Name

administrator

Password

pillar

 

To login to the GUI application, use one of the following options:

● For a newly installed Pillar Axiom system in which the Pilot IP address has not been changed, use an address of 10.0.0.2, which was set at the factory.  Typically, this address is what you also used to download the GUI application.
● If the Pilot IP address has been changed to a customer-specific address, use that address.

Alternatively, if you configured the IP address to a DNS host name, you can use that host name to log into the Pillar Axiom system.

 

Tip: If you forget the Primary system administrator password, you can reset it using either of these two methods:

● Use a Type 1 Administrator account, if one exists, to reset the password. A support administrator cannot reset the Primary system administrator password.
● Contact the Oracle Pillar Customer Support for the encrypted file (for resetting the password). The Oracle Pillar Customer Support will send you the encrypted file and give you instructions on how to install the file.

 

After logging in to the Pillar Axiom system, you can perform administrator tasks.
At any given time, the following number of administrator sessions can be active:

● 5 active sessions for each administrator account
● 25 total at any given time

Note: The default time-out period is 20 minutes. When a session is inactive for more than the time-out period, the system terminates that session.

 