Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1535372.1
Update Date:2016-09-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1535372.1 :   Sun Storage 7000 Unified Storage System: Avoid configuring zpools with mixed disk sizes  


Related Items
  • Sun ZFS Storage 7320
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun ZFS Storage 7420
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Goal
Solution
References


Created from <SR 3-6704087781>

Applies to:

Sun Storage 7310 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7210 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases]
Sun Storage 7410 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Goal

How can we remove just that one shelf (undo if you will) so that we can re-add it as it's own pool to get the full use of the larger drives?
 

Solution

The only way to do this is to destroy the pool.   You will loose the data on the Pool unless you back it up beforehand.   You can then configure two new pools to your specifications.

 
How many JBODS?

=> From hw (BUI - Maintenance > Hardware) (CLI - maintenance hardware list)

chassis-000   node-name     ok                Oracle                  Sun ZFS Storage 7420                     node-serial-number                   --  
chassis-001  xxxxFMD00L     ok        Sun Microsystems, Inc.  Sun Disk Shelf (SAS-2)                           xxxxFMD00L                    7200
chassis-002  xxxxFMD00U     ok        Sun Microsystems, Inc.  Sun Disk Shelf (SAS-2)                           xxxxFMD00U                    7200
chassis-003  xxxxFMD03V     ok        Sun Microsystems, Inc.  Sun Disk Shelf (SAS-2)                           xxxxFMD03V                    7200
-bash-4.1$

 

What raid is being used?

(BUI - Configuration > Storage) (CLI - configuration storage ls  -  profile = raidz2)

| 7.1) List of zpools available
+------------------------------------------
NAME     SIZE  ALLOC   FREE    CAP  DEDUP  HEALTH  ALTROOT
pool-0   136T  55.8T  80.0T    41%  1.00x  ONLINE  -  ================>  !! to check the "size"
system   464G  89.7G   374G    19%  1.00x  ONLINE  -


See also RAID-Z Storage Pool Configuration - http://docs.oracle.com/cd/E23823_01/html/819-5461/gcfof.html#gamtu

=> From zpool   6 vdev x raidz2

pool-0                     ONLINE       0     0     0
 raidz2-0                 ONLINE       0     0     0
   c6txxxxxxxx213E365Fd0  ONLINE       0     0     0 xxxxFMD00L bay=5
   c6txxxxxxxx40B1E89Fd0  ONLINE       0     0     0 xxxxFMD00U bay=4
   c6txxxxxxxx40B1F953d0  ONLINE       0     0     0 xxxxFMD00U bay=17
   c6txxxxxxxx40B1F807d0  ONLINE       0     0     0 xxxxFMD00L bay=15
   c6txxxxxxxx40B7A3C7d0  ONLINE       0     0     0 xxxxFMD00U bay=13
   c6txxxxxxxx40B2B95Bd0  ONLINE       0     0     0 xxxxFMD00L bay=4
   c6txxxxxxxx40B8A6D3d0  ONLINE       0     0     0 xxxxFMD00U bay=0
   c6txxxxxxxx40B2FE57d0  ONLINE       0     0     0 xxxxFMD00L bay=7
   c6txxxxxxxx40B8A827d0  ONLINE       0     0     0 xxxxFMD00U bay=5
   c6txxxxxxxx40B7ADF7d0  ONLINE       0     0     0 xxxxFMD00L bay=16
   c6txxxxxxxx40B8AB9Bd0  ONLINE       0     0     0 xxxxFMD00U bay=16
   c6txxxxxxxx40B7E973d0  ONLINE       0     0     0 xxxxFMD00L bay=8
   c6txxxxxxxx40B8B49Fd0  ONLINE       0     0     0 xxxxFMD00U bay=22
   c6txxxxxxxx40B7E997d0  ONLINE       0     0     0 xxxxFMD00L bay=19
 raidz2-1                 ONLINE       0     0     0
   c6txxxxxxxx40B8B837d0  ONLINE       0     0     0 xxxxFMD00U bay=21
   c6txxxxxxxx40B7F11Fd0  ONLINE       0     0     0 xxxxFMD00L bay=17
   c6txxxxxxxx40B8BDB3d0  ONLINE       0     0     0 xxxxFMD00U bay=19
   c6txxxxxxxx40B8AE07d0  ONLINE       0     0     0 xxxxFMD00L bay=0
   c6txxxxxxxx40B8C0F7d0  ONLINE       0     0     0 xxxxFMD00U bay=1
   c6txxxxxxxx40B8CFDFd0  ONLINE       0     0     0 xxxxFMD00L bay=2
   c6txxxxxxxx40B8D12Bd0  ONLINE       0     0     0 xxxxFMD00U bay=23
   c6txxxxxxxx40B8D1F3d0  ONLINE       0     0     0 xxxxFMD00L bay=10
   c6txxxxxxxx40B30CD3d0  ONLINE       0     0     0 xxxxFMD00U bay=20
   c6txxxxxxxx40B31BF7d0  ONLINE       0     0     0 xxxxFMD00L bay=14
   c6txxxxxxxx40B30D63d0  ONLINE       0     0     0 xxxxFMD00U bay=14
   c6txxxxxxxx40B95B8Bd0  ONLINE       0     0     0 xxxxFMD00L bay=11
   c6txxxxxxxx40B30E93d0  ONLINE       0     0     0 xxxxFMD00U bay=9
   c6txxxxxxxx40B921A3d0  ONLINE       0     0     0 xxxxFMD00L bay=13
 raidz2-2                 ONLINE       0     0     0
   c6txxxxxxxx40B31EF3d0  ONLINE       0     0     0 xxxxFMD00U bay=12
   c6txxxxxxxx40B955F7d0  ONLINE       0     0     0 xxxxFMD00L bay=1
   c6txxxxxxxx40B90C5Bd0  ONLINE       0     0     0 xxxxFMD00U bay=11
   c6txxxxxxxx40B8337Bd0  ONLINE       0     0     0 xxxxFMD00L bay=9
   c6txxxxxxxx40B91FA3d0  ONLINE       0     0     0 xxxxFMD00U bay=2
   c6txxxxxxxx40B9182Bd0  ONLINE       0     0     0 xxxxFMD00L bay=6
   c6txxxxxxxx40B96D37d0  ONLINE       0     0     0 xxxxFMD00U bay=3
   c6txxxxxxxx40B9616Fd0  ONLINE       0     0     0 xxxxFMD00L bay=3
   c6txxxxxxxx40B309D3d0  ONLINE       0     0     0 xxxxFMD00U bay=10
   c6txxxxxxxx40B83227d0  ONLINE       0     0     0 xxxxFMD00L bay=12
   c6txxxxxxxx40B891BFd0  ONLINE       0     0     0 xxxxFMD00U bay=8
   c6txxxxxxxx40B92517d0  ONLINE       0     0     0 xxxxFMD00L bay=18
   c6txxxxxxxx40B910F7d0  ONLINE       0     0     0 xxxxFMD00U bay=7
   c6txxxxxxxx40B924AFd0  ONLINE       0     0     0 xxxxFMD00U bay=15
 raidz2-5                 ONLINE       0     0     0
   c6txxxxxxxxxE4B2998d0  ONLINE       0     0     0 xxxxFMD03V bay=10
   c6txxxxxxxxxE4E5A10d0  ONLINE       0     0     0 xxxxFMD03V bay=14
   c6txxxxxxxxxE4E9AC8d0  ONLINE       0     0     0 xxxxFMD03V bay=19
   c6txxxxxxxxxE4E9068d0  ONLINE       0     0     0 xxxxFMD03V bay=7
   c6txxxxxxxxxE4EBB1Cd0  ONLINE       0     0     0 xxxxFMD03V bay=13
   c6txxxxxxxxxE4EBFACd0  ONLINE       0     0     0 xxxxFMD03V bay=5
   c6txxxxxxxxxE4ED1E8d0  ONLINE       0     0     0 xxxxFMD03V bay=11
   c6txxxxxxxxxE4EEE50d0  ONLINE       0     0     0 xxxxFMD03V bay=22
   c6txxxxxxxxxE4EF1E8d0  ONLINE       0     0     0 xxxxFMD03V bay=23
   c6txxxxxxxxxE4EF1FCd0  ONLINE       0     0     0 xxxxFMD03V bay=21
   c6txxxxxxxxxE4EF178d0  ONLINE       0     0     0 xxxxFMD03V bay=17
 raidz2-6                 ONLINE       0     0     0
   c6txxxxxxxxxE4F1E64d0  ONLINE       0     0     0 xxxxFMD03V bay=6
   c6txxxxxxxxxE4FC1CCd0  ONLINE       0     0     0 xxxxFMD03V bay=12
   c6txxxxxxxxxE4FCF24d0  ONLINE       0     0     0 xxxxFMD03V bay=15
   c6txxxxxxxxxE45C618d0  ONLINE       0     0     0 xxxxFMD03V bay=0
   c6txxxxxxxxxE444CA4d0  ONLINE       0     0     0 xxxxFMD03V bay=2
   c6txxxxxxxxxE501C7Cd0  ONLINE       0     0     0 xxxxFMD03V bay=9
   c6txxxxxxxxxE502F7Cd0  ONLINE       0     0     0 xxxxFMD03V bay=1
   c6txxxxxxxxxE3682E0d0  ONLINE       0     0     0 xxxxFMD03V bay=8
   c6txxxxxxxxxE5030D0d0  ONLINE       0     0     0 xxxxFMD03V bay=4
   c6txxxxxxxxxE50362Cd0  ONLINE       0     0     0 xxxxFMD03V bay=16
   c6txxxxxxxxxE492680d0  ONLINE       0     0     0 xxxxFMD03V bay=3
logs
 c6txxxxxxxx30023D67d0    ONLINE       0     0     0 xxxxFMD00L bay=21
 c6txxxxxxxx30037D66d0    ONLINE       0     0     0 xxxxFMD00L bay=20
cache
 c1t2d0                   ONLINE       0     0     0node-serial-numberbay=2
 c1t3d0                   ONLINE       0     0     0node-serial-numberbay=3
spares
 c6txxxxxxxx40B968DFd0    AVAIL    xxxxFMD00U bay=6
 c6txxxxxxxx40B9228Fd0    AVAIL    xxxxFMD00U bay=18
 c6txxxxxxxxxE500530d0    AVAIL    xxxxFMD03V bay=20
 c6txxxxxxxxxE503748d0    AVAIL    xxxxFMD03V bay=18


What is the size of the disk in the pool? 


=> To check the "size" (BUI - Maintenance > Hardware) (CLI - maintenance hardware list)

a) From hw, they can see the details of the disks and JBOD:

chassis-001  xxxxFMD00L     ok        Sun Microsystems, Inc.  Sun Disk Shelf (SAS-2)                           xxxxFMD00L                    7200

disk-000     HDD 0          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0NZ8        9WM80NZ8  7200
disk-001     HDD 1          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx1HKV        9WM81HKV  7200
disk-002     HDD 2          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0PTV        9WM80PTV  7200
disk-003     HDD 3          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx1HVX        9WM81HVX  7200
disk-004     HDD 4          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx03ML        9WM803ML  7200
disk-005     HDD 5          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxGJXS        9WM1GJXS  7200
disk-006     HDD 6          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0LVM        9WM80LVM  7200
disk-007     HDD 7          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZL1E        9WM7ZL1E  7200
disk-008     HDD 8          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0G6P        9WM80G6P  7200
disk-009     HDD 9          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx09QJ        9WM809QJ  7200
disk-010     HDD 10         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0KVM        9WM80KVM  7200
disk-011     HDD 11         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx1HNB        9WM81HNB  7200
disk-012     HDD 12         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx09PH        9WM809PH  7200
disk-013     HDD 13         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0MJ7        9WM80MJ7  7200
disk-014     HDD 14         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZFJ3        9WM7ZFJ3  7200
disk-015     HDD 15         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZYQT        9WM7ZYQT  7200
disk-016     HDD 16         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx13F4        9WM813F4  7200
disk-017     HDD 17         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0GEJ        9WM80GEJ  7200
disk-018     HDD 18         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0MKP        9WM80MKP  7200
disk-019     HDD 19         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0G7V        9WM80G7V  7200
disk-020     HDD 20         ok        STEC                    ZeusIOPs                                         xxxxxxx2CA3E                  --  
disk-021     HDD 21         ok        STEC                    ZeusIOPs                                         xxxxxxx163C7                  --  
disk-022     HDD 22         absent    -                       -                                                -                             --  
disk-023     HDD 23         absent    -                       -                                                -                             --  
fan-000      FAN 0/0        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxxL0148          
fan-001      FAN 0/1        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxxL0148          
fan-002      FAN 1/0        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxxL0147          
fan-003      FAN 1/1        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxxL0147          
psu-000      PSU 0          ok        Sun Microsystems, Inc.  3002276                                          xxxxxxx-xxxxxL0148          
psu-001      PSU 1          ok        Sun Microsystems, Inc.  3002276                                          xxxxxxx-xxxxxL0147          
slot-000     SIM 0          ok        Sun Microsystems, Inc.  3753633                                          xxxxxxx-xxxxxC102C          
slot-001     SIM 1          ok        Sun Microsystems, Inc.  3753633                                          xxxxxxx-xxxxxC109B          

chassis-002  xxxxFMD00U     ok        Sun Microsystems, Inc.  Sun Disk Shelf (SAS-2)                           xxxxFMD00U                    7200

disk-000     HDD 0          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0NPL        9WM80NPL  7200   =====>  ST32000SSSUN2.0T ==> 2.0T
disk-001     HDD 1          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0PRT        9WM80PRT  7200
disk-002     HDD 2          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0MG0        9WM80MG0  7200
disk-003     HDD 3          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx1N6A        9WM81N6A  7200
disk-004     HDD 4          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZYB7        9WM7ZYB7  7200
disk-005     HDD 5          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0NRN        9WM80NRN  7200
disk-006     HDD 6          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxXNCQ        9WM7XNCQ  7200
disk-007     HDD 7          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0LYV        9WM80LYV  7200
disk-008     HDD 8          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0878        9WM80878  7200
disk-009     HDD 9          ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZFTH        9WM7ZFTH  7200
disk-010     HDD 10         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZFQ1        9WM7ZFQ1  7200
disk-011     HDD 11         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0LLY        9WM80LLY  7200
disk-012     HDD 12         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZKZQ        9WM7ZKZQ  7200
disk-013     HDD 13         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0CEY        9WM80CEY  7200
disk-014     HDD 14         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZFNR        9WM7ZFNR  7200
disk-015     HDD 15         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0MMM        9WM80MMM  7200
disk-016     HDD 16         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0NSQ        9WM80NSQ  7200
disk-017     HDD 17         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZYS7        9WM7ZYS7  7200
disk-018     HDD 18         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0MKC        9WM80MKC  7200
disk-019     HDD 19         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0PLA        9WM80PLA  7200
disk-020     HDD 20         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxxZFSP        9WM7ZFSP  7200
disk-021     HDD 21         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0PBN        9WM80PBN  7200
disk-022     HDD 22         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0P6Z        9WM80P6Z  7200
disk-023     HDD 23         ok        SEAGATE                 ST32000SSSUN2.0T                                 xxxxxxxx0KTZ        9WM80KTZ  7200
fan-000      FAN 0/0        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxXL0335          
fan-001      FAN 0/1        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxXL0335          
fan-002      FAN 1/0        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxXL0141          
fan-003      FAN 1/1        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxXL0141          
psu-000      PSU 0          ok        Sun Microsystems, Inc.  3002276                                          xxxxxxx-xxxxXL0335          
psu-001      PSU 1          ok        Sun Microsystems, Inc.  3002276                                          xxxxxxx-xxxxXL0141          
slot-000     SIM 0          ok        Sun Microsystems, Inc.  3753633                                          xxxxxxx-xxxxQC1109          
slot-001     SIM 1          ok        Sun Microsystems, Inc.  3753633                                          xxxxxxx-xxxxQC1008          

chassis-003  xxxxFMD03V     ok        Sun Microsystems, Inc.  Sun Disk Shelf (SAS-2)                           xxxxFMD03V                    7200

disk-000     HDD 0          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxx7BKLD        YVH7BKLD  7200   ========> Notice H7230AS60SUN3.0T  ==> 3.0T
disk-001     HDD 1          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxE32AD        YVHE32AD  7200
disk-002     HDD 2          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxx6KEAD        YVH6KEAD  7200
disk-003     HDD 3          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxx9745K        YVH9745K  7200
disk-004     HDD 4          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxE352D        YVHE352D  7200
disk-005     HDD 5          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxD9KZD        YVHD9KZD  7200
disk-006     HDD 6          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxDHWJD        YVHDHWJD  7200
disk-007     HDD 7          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxD6EDD        YVHD6EDD  7200
disk-008     HDD 8          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxYZB2K        YVGYZB2K  7200
disk-009     HDD 9          ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxE1U3D        YVHE1U3D  7200
disk-010     HDD 10         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxAAELD        YVHAAELD  7200
disk-011     HDD 11         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxDATMD        YVHDATMD  7200
disk-012     HDD 12         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxDVSWD        YVHDVSWD  7200
disk-013     HDD 13         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxD98KD        YVHD98KD  7200
disk-014     HDD 14         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxD2U6D        YVHD2U6D  7200
disk-015     HDD 15         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxDWNED        YVHDWNED  7200
disk-016     HDD 16         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxE3J4D        YVHE3J4D  7200
disk-017     HDD 17         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxDDWTD        YVHDDWTD  7200
disk-018     HDD 18         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxE3LED        YVHE3LED  7200
disk-019     HDD 19         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxD73UD        YVHD73UD  7200
disk-020     HDD 20         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxE080D        YVHE080D  7200
disk-021     HDD 21         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxDDXVD        YVHDDXVD  7200
disk-022     HDD 22         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxDDP8D        YVHDDP8D  7200
disk-023     HDD 23         ok        HITACHI                 H7230AS60SUN3.0T                                 xxxxxxxDDXPD        YVHDDXPD  7200
fan-000      FAN 0/0        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxxL0594          
fan-001      FAN 0/1        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxxL0594          
fan-002      FAN 1/0        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxxL0586          
fan-003      FAN 1/1        ok        Sun Microsystems, Inc.  -                                                xxxxxxx-xxxxxL0586          
psu-000      PSU 0          ok        Sun Microsystems, Inc.  3002276                                          xxxxxxx-xxxxxL0594          
psu-001      PSU 1          ok        Sun Microsystems, Inc.  3002276                                          xxxxxxx-xxxxxL0586          
slot-000     SIM 0          ok        Sun Microsystems, Inc.  3753633                                          xxxxxxx-xxxxxC1198          
slot-001     SIM 1          ok        Sun Microsystems, Inc.  3753633                                          xxxxxxx-xxxxxC131F          

 

How much space we should see from adding a shelf of 3TB drives (vs 2TB) ?   ... it depends on layout set up when data pool is created, mirror, raidz, etc ..


In general we can check with command " zpool list" and example here:

How many pools configured?

| 7.1) List of zpools available
+------------------------------------------
NAME     SIZE  ALLOC   FREE    CAP  DEDUP  HEALTH  ALTROOT
pool-0   136T  55.8T  80.0T    41%  1.00x  ONLINE  -                 ================>  !! to check the "size"  Be careful check "size" word and zfs.
system   464G  89.7G   374G    19%  1.00x  ONLINE  -

 

Sun ZFS Storage 7000 System Administration Guide  
http://docs.oracle.com/cd/E26765_01/html/E26397/configuration__storage.html


Configuration Rules and Guidelines For optimal performance, keep in mind the following:   

Rule 1 -- All "data" disks contained within a head node or JBOD must have the same rotational speed (media rotation rate RPM's 7200, 10K or 15K).
The ZFSSA software will detect misconfigurations and generate a fault for the condition.  

Recommendation 1 -- Due to unpredictable performance issues, avoid mixing different disk rotational speeds within the same pool.  

Recommendation 2 -- For optimal performance, do not combine JBODs with different disk rotational speeds on the same SAS fabric (HBA connection).
Such a mixture operates correctly, but likely results in slower performance of the faster devices.

Recommendation 3 -- When configuring storage pools that contain data disks of different capacities (size: 500GB, 600GB, 1TB, 2TB, 3TB),
ZFS will in some cases will be limited to that of the smallest capacity disk for some or all of the disks within the storage pool,
thereby reducing the overall expected capacity.
The sizes used will depend on the storage profile, layout, and combination of devices.


Avoid mixing different disk capacities within the same pool. 

Note: If expanding an EXISTING pool, the capacity of the drives will be maintained. The usable capacity (of a mixed pool) will be the sum of the corresponding vdev sizes, each vdev composed of same size drives only.

References

https://mediawiki.us.oracle.com/systemsfaq/index.php/Oracle_ZFS_Storage_Appliance_Storage_Media

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback