Solution Type Technical Instruction Sure Solution 1534242.1 : How Can HBA Firmware Warnings During a V2.0.1 Reimage Be Resolved?
In this Document
Applies to:Big Data Appliance Hardware - Version All Versions and laterBig Data Appliance Integrated Software - Version 2.0.1 to 2.0.1 [Release 2.0] Linux x86-64 GoalIf errors/warnings like those below are reported after a BDA V1.0.3 with Image V2.0.1 being freshly installed on the rack with reimagerack show: WARNING: Insufficient disk controller firmware minor version : 0048
INFO: Minimum disk controller firmware minor version : 0079 How can the HBA firmware warnings during a V2.0.1 reimage be resolved? SolutionThis indicates that a disk controller firmware update is required. # setup-root-ssh
# dcli bdaupdatefw -l
# dcli reboot
# ./reimagerack