Solution  1532148.1 :   Fujitsu M10-4S - How to Replace an Operation Panel  


Related Items
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: CAP for onsite Engineers.

Applies to:

Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases]
Oracle Solaris on SPARC (64-bit)

Goal

 To assist FSE in replacing Operation Panel.

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1532148.1
********************************************************************************

Solution

 DISPATCH INSTRUCTIONS
   WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: FSE should have completed M10 training.
   TIME ESTIMATE:  60 minutes
   TASK COMPLEXITY: 3

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
   PROBLEM OVERVIEW: Replacement of Operation Panel.
   WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:
Inactive/cold maintenance

Maintenance work is performed while the physical partition to which the maintenance-target FRU belongs is powered off and the

input power of the cabinet on which the target FRU is mounted is off (power cord is disconnected
System-stopped maintenance

Maintenance work is performed while all the physical partitions are powered off and input power of the cabinet on which the target FRU is mounted is off (power cord is disconnected).


   WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Note the following points when you replace the operation panel:
When you conduct inactive/cold maintenance or system-stopped maintenance,
make sure that you set the mode switch of the operation panel to the Service mode
before you start the maintenance.

1. The customer should conduct an orderly shutdown of the system software and the PPAR

          XSCF>  poweroff -p 0

2. Verify the ppar has been shutdown with

         XSCF> showboards -a

3. Check that the POWER LEDs on all cabinets composing the system is off.
4. Display the maintenance menu(user must have fieldeng privileges)
    XSCF> replacefru
5. Select the maintenance-target cabinet
6. Remove all power cords from the PSU backplane unit of the maintenance-target cabinet.
7. Check the ID switch on the operation panel and record the BB-ID set for the maintenance-target cabinet.
8. Lower the cable support.
9. Remove all the cables connected to the external interface.
The cables to be removed are as follows.
■ Interface cable connected to the PCI Express (PCIe) card
■ Crossbar cable
■ XSCF connection cable
■ XSCF DUAL cable
■ LAN cable
Note - Be sure to disconnect the cable of the external interface after taking notes on the
connection position in order to reconnect the cable correctly.  Recommend bringing postit/sticky paper.
10. Remove all the PCIe card cassettes or the filler units of the PCIe.  make sure to take notes of location of PCIe for reinstallment.
11. Remove all crossbar units (XBU)
12. Loosen three screws that secure the mounting frame of the crossbar unit to remove the frame. (These are the green pop-out spring screws)
13. Loosen one screw of the CPU memory unit and lower the right and left levers to the horizontal position.
14. Pull out the CPU memory unit by about 10 cm (3.9 in.), it doesn't need to be completely out.
15. Remove the FRONT cover and pull the PSUs out about 4in. they do NOT need to be removed.  All the FANS will need to be removed.

Removing the Operator Panel
16. Loosen two screws (green spring pop-out) of the PSU backplane unit and partially pull out the PSU backplane unit.
17. Remove one cable of the operation panel and loosen one screw.
18. Pull out the operation panel forward to remove it.
19. Reinstall new operation panel and reinstall all components.

OBTAIN CUSTOMER ACCEPTANCE
   WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

PARTS NOTE:

REFERENCE INFORMATION:

Service Manual - http://docs.oracle.com/cd/E38160_01

 