![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1530753.1 : Sun Storage 7000 Unified Storage System: Recovery procedure for mismatched Infiniband (ibp) network device names
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun ZFS Storage 7420 - Version All Versions and laterSun Storage 7410 Unified Storage System - Version All Versions and later Sun Storage 7310 Unified Storage System - Version All Versions and later Sun ZFS Storage 7320 - Version All Versions and later 7000 Appliance OS (Fishworks) GoalDescribe the procedure to achieve the rebuilding of the path_to_inst file so that both heads of a cluster enumerate the ibp devices identically
In this case I am choosing head2 to reconfigure the path_to_inst as the path_to_inst on Head1 is shown in the correct order: Head1 path_to_inst: "/pci@0,0/pci8086,340c@5/pci15b3,673c@0/ibport@1,0,ipib" 0 "ibp"
"/pci@0,0/pci8086,340c@5/pci15b3,673c@0/ibport@2,0,ipib" 1 "ibp" "/pci@0,0/pci8086,340e@7/pci15b3,673c@0/ibport@1,0,ipib" 2 "ibp" "/pci@0,0/pci8086,340e@7/pci15b3,673c@0/ibport@2,0,ipib" 3 "ibp" "/pci@1,0/pci8086,340c@5/pci15b3,673c@0/ibport@1,0,ipib" 4 "ibp" "/pci@1,0/pci8086,340c@5/pci15b3,673c@0/ibport@2,0,ipib" 5 "ibp"
Compared with head2: Head2 path_to_inst: "/pci@0,0/pci8086,340c@5/pci15b3,673c@0/ibport@1,0,ipib" 2 "ibp"
"/pci@0,0/pci8086,340c@5/pci15b3,673c@0/ibport@2,0,ipib" 3 "ibp" "/pci@0,0/pci8086,340e@7/pci15b3,673c@0/ibport@1,0,ipib" 4 "ibp" "/pci@0,0/pci8086,340e@7/pci15b3,673c@0/ibport@2,0,ipib" 5 "ibp" "/pci@1,0/pci8086,340c@5/pci15b3,673c@0/ibport@1,0,ipib" 0 "ibp" "/pci@1,0/pci8086,340c@5/pci15b3,673c@0/ibport@2,0,ipib" 1 "ibp
SolutionPlease use the resolution procedure given in the following document: Note: Partners will need to open an Service Request if they cannot access KM 1560329.1 for Oracle TSC Support to assist.
CAUTION : If there is more than one IB fabric, running the solution may cause the IB network configuration to become incorrect.
References<BUG:17194712> - NEED RCA AND FIX/WORKAROUND TOCORRECT PATH_TO_INST ISSUE<BUG:16201968> - PATH_TO_INST PROBLEMS WITH ZFSSAS <NOTE:1560329.1> - Sun Storage 7000 Unified Storage System: Device Enumeration Mismatch when inserting Additional Network Cards in a Cluster Attachments This solution has no attachment |
||||||||||||||||
|