Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1530441.1
Update Date:2017-01-09
Keywords:

Solution Type  Technical Instruction Sure

Solution  1530441.1 :   How to Remove and Replace a SPARC T5-1B or Netra T5-1B System Battery:ATR:1530441.1:0  


Related Items
  • Netra SPARC T5-1B Server Module
  •  
  • Sun Blade 6000 System
  •  
  • SPARC T5-1B
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Blade 6000 System - Version All Versions and later
SPARC T5-1B - Version All Versions and later
Netra SPARC T5-1B Server Module - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a SPARC T5-1B System Battery

********************************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1530441.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW: Failed T5-1B or Netra T5-1B system battery

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.


Prepare for service by performing the following tasks:

    Shut Down the Oracle Solaris OS
    Prepare the Server Module for Removal
    Remove the Server Module From the Modular System
    Remove the Cover
    ESD Safety Measures


WHAT ACTIONS ARE REQUIRED:

1. Push the top of the battery forward, then lift the battery from the holder.

2. Install the replacement battery with the positive (+) side facing the nearby SP.

3. Return the server module to operation.

4. Set the clock’s day and time.

For example:

-> set /SP/clock datetime=061716192012
-> show /SP/clock

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Boot system and monitor boot sequence for errors. Test functionality of system. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SPARC_T5_1B/components.html#Batteries

 

https://support.oracle.com/handbook_private/Systems/Netra_T5_1B/components.html#Batteries

REFERENCE INFORMATION:
SPARC T5-1B Server Module Service Manual at http://docs.oracle.com/cd/E35199_01/index.html

Netra T5-1B Service Module Service Manual at http://docs.oracle.com/cd/E35777_01/index.html