Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1530046.1
Update Date:2018-03-27
Keywords:

Solution Type  Technical Instruction Sure

Solution  1530046.1 :   Fujitsu M10-4S - How to Replace a XSCF Dual Cable from a Crossbar to a Crossbar  


Related Items
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: M10 Cap

Applies to:

Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 CAP PROBLEM OVERVIEW: How to replace a XSCF Dual Cable  from a    Crossbar box    to  a   Crossbar box
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID:  1530046.1
********************************************************************************

Solution

 DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

Field training in M10-4S servers

TASK COMPLEXITY: 2

Time Estimate: 30 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:  

While all  types of maintenance are available for the XSCF Dual Cable  from a    Crossbar box    to  a   Crossbar box, the easiest is Active/hot maintenance.
For the other maintenance types see the M10 Service Manual 

 

1.  Execute the XSCF> replacefru          command to isolate the Standby  Cross Bar unit

2.  On the Standby Crossbar box remove the faulted XSCF Dual cable by pushing the lock release buttons on the both sides of the cable and disconnecting the cable.

3.  Trace the cable to the Master XSCF and disconnect the cable from it

4.  Install the replacement cable.

5.  Execute the XSCF> replacefru          command to restore the Standby  Cross Bar unit to service

 

 

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Verify the status of all domains.

PARTS NOTE:

REFERENCE INFORMATION:

Service Manual - http://docs.oracle.com/cd/E38160_01