Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1530043.1
Update Date:2016-01-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1530043.1 :   M10-4/M10-4S Server - How to Replace a Power Supply  


Related Items
  • Fujitsu M10-4S
  •  
  • Fujitsu M10-4
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases]
Fujitsu M10-4 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 M10-4/M10-4S server - How to replace a power supply

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1530043.1
********************************************************************************

Solution

 DISPATCH INSTRUCTIONS


WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Engineer should be M10-4/M10-4S trained

TIME ESTIMATE: 20 minutes

TASK COMPLEXITY:1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW:


WHAT STATE SHOULD THE SYSTEM BE IN PRIOR TO PERFORMING THE RESOLUTION ACTIVITY?:

This activity can be performed as an active/hot replacement or as a cold replacement

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Active Replacement:

1) Log in to XSCF and execute the replacefru command. ( Must have fieldeng permissions )

2) Select PSU.

3) Select the number of the faulted PSU.

4) Perform the operation according to the instructions displayed in the maintenance menu.

Note: See 'Physical removal of the power supply' below

5) Once the replacement is complete check the status to ensure no further fru's are in degraded or faulted status.

XSCFgt; showhardconf -M

XSCFgt; showstatus

 

Physical removal of the power supply

  1. Remove the front cover

  2. Remove the power cords from the bad PSU

  3. Loosen the captive screw on the bad PSU

  4. Pull the lever on the PSU, support the PSU from underneath and use the lever to pull it out of the chassis.

 

Physical installation of the power supply

  1. Check to see if the PSU shipped with a temporary protective covering over its connectors. It so, remove the covering.

  2. Support the power supply from underneath, and slide it into the chassis firmly but not forcefully

  3. Close the lever and tighten the screw

  4. Connect the power cords

  5. Install the front cover

 

Cold Replacement

Other than powering down the server, there are no special steps for cold replacement. Once the server has been powered down, perform the physical removal and physical installation procedures as outlined above

OBTAIN CUSTOMER ACCEPTANCE


WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

No additional work is required

PARTS NOTE: None

REFERENCE INFORMATION:

Service Manual - http://docs.oracle.com/cd/E38160_01

For a complete procedure, please see the M10-4S service manual

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback