![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1530043.1 : M10-4/M10-4S Server - How to Replace a Power Supply
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential). Applies to:Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases]Fujitsu M10-4 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalM10-4/M10-4S server - How to replace a power supply ******************************************************************************** SolutionDISPATCH INSTRUCTIONS
TIME ESTIMATE: 20 minutes TASK COMPLEXITY:1 PROBLEM OVERVIEW:
This activity can be performed as an active/hot replacement or as a cold replacement WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: Active Replacement: 1) Log in to XSCF and execute the replacefru command. ( Must have fieldeng permissions ) 2) Select PSU. 3) Select the number of the faulted PSU. 4) Perform the operation according to the instructions displayed in the maintenance menu. Note: See 'Physical removal of the power supply' below 5) Once the replacement is complete check the status to ensure no further fru's are in degraded or faulted status. XSCFgt; showhardconf -M XSCFgt; showstatus
Physical removal of the power supply
Physical installation of the power supply
Cold Replacement Other than powering down the server, there are no special steps for cold replacement. Once the server has been powered down, perform the physical removal and physical installation procedures as outlined above OBTAIN CUSTOMER ACCEPTANCE
No additional work is required Service Manual - http://docs.oracle.com/cd/E38160_01 For a complete procedure, please see the M10-4S service manual
Attachments This solution has no attachment |
||||||||||||||
|