Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1529544.1
Update Date:2018-04-23
Keywords:

Solution Type  Technical Instruction Sure

Solution  1529544.1 :   Mx-32 How to Replace a Faulty CPU memory board (CMU) filler panel  


Related Items
  • SPARC M5-32
  •  
  • SPARC M6-32
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

SPARC M5-32 - Version All Versions and later
SPARC M6-32 - Version All Versions and later
Oracle SuperCluster M6-32 Hardware - Version All Versions and later
Information in this document applies to any platform.

Goal

CAP PROBLEM OVERVIEW: Mx-32 How to Replace a Faulty CPU/memory board (CMU) filler panel



To report errors or request improvements on this procedure, please go to My Oracle Support, and  put a comment on Doc ID: 1529544.1 .


 

ESD Caution:
  • Circuit boards and drives contain electronic components that are  extremely sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work environment can destroy the components located on these boards. Do not touch the components along their connector edges.
  • Use a Antistatic Wrist strap. Attach one end of the strap to your wrist and the other end to the chassis, depending on what type of strap you use, with the adhesive end or the metal plug.
  • Use an Antistatic Mat. Place ESD-sensitive components such as motherboards, memory, and other PCBs on an antistatic mat.

 

Contamination Caution:

  • Dust particles of packaging material are number one cause of datacenter contamination. Make sure to remove all packaging material, up to the ESD safe
  • packaging material, while still being outside the datacenter.

 

Caution – Do not remove more than one CMU (or CMU filler panel) at a time. Fill the empty slot within two minutes, or the server might overheat and shut down.

 

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED: Mx-32 Product Training/Experience

TASK COMPLEXITY: 2

TIME ESTIMATE: 45 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?

This activity can be performed as an active/hot replacement or as a cold replacement

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

 

1. Remove the CMU filler panel

a. Rotate the extraction levers to the horizontal position.
b. Pull the CMU filler panel out of the slot until the carrying handle is exposed.
c. Unfold the carrying handle.
d. Holding the carrying handle

2. Reinstall the CMU filler panel

a. Unfold the CMU filler panel carrying handle and use the carrying handle and the extraction knob to place the filler panel in the slot.
b. Fold the carrying handle down into the top of the CMU filler panel.
c. Squeeze the latches of the extraction lever handles to unlock them.
d. Rotate the extraction levers to the horizontal position.
e. Use the extraction knob to slide the CMU into the slot until CMU nears the end of the slot and the extraction levers start to close.
f. Close the extraction levers to complete the insertion and lock the CMU filler panel in place.

3. Return the faulted component to Oracle.

 

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

 

 

======================== Other info =====================