Goal
Fix


Applies to:

Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

Does the SL500 support mixing LTO and Mixed Media Modules in the same library?

Fix

  A customer has a Base and 1 DEM for LTO only.
  They want to remove the DEM and replace it with a Mixed Media DEM with two SDLT drives and two LTO drives.

There has been some confusion as to whether LTO only and Multi-Media modules can be mixed on the same SL500.  There is documentation that states they should not be mixed.

The Installation Manual -  seems clear don't mix LTO and MM DEM and CEM's .
But to clarify, are we saying don't mix any LTO Base or MM with the other type DEM and CEM.
Sales has sold a site to take out the existing LTO DEM and put in a MM DEM to a LTO Base.
There seems to be some wiggle room in that we don't specify Base and DEM and CEM   and only get specific on expansion modules ?


LTO Library Cartridge Slots
Caution – Firmware problems: You can not mix LTO and mixed-media arrays and magazines within the same library. If you add expansion modules, the new modules must have the same type arrays as the existing modules.

“LTO Only Version” DEM's and CEM's cannot be mixed with ”Mixed Media Version” DEM's and CEM's.

Product Engineering stated it should work and the library is smart enough to figure it out but it has not been tested.

===========================================================

Local engineer did the installation as requested and found positive results supporting LTO only Base and Mixed Media Module with 2 types of drives working without issue.

The original configuration was, BASE plus one DEM, LTO Type.
They shut off power and opened the Front Door, removed the Cell arrays and installed the MM (Multi-Media) type Cell arrays to the DEM only.  Then Removed the CAP Assembly and replaced it with the CAP unit from the MM DEM.  Then replaced the Target Bar from the drive end with the same from the MM DEM.  Then removed two LTO-3 Drives and replaced those with two SDLT-320 Drives.  Then Powered On the SL500 with the Base Module configured for LTO type and the DEM configured for MM type.
The SL500 Booted up like normal.  No Errors on any part.

Below is the configuration information from the library after the module change over.

SERVICE>> version
Library Hardware Information
  Library Vendor:       STK
  Library Model:        SL500
  Serial Number:        559000102112
  Host Interface:       Fibre
Library Active Software Information
  Firmware Version:     1373 (6.53.00)

OK
SERVICE>> lib getconfig
Library Configuration
  Unit Type                      SL500
  Total number of modules        2
    Module 1 type                25                                       (Module types are defined here)                                                            25 BASE module with drives in the back
    Module 2 type                34                                       SL500 - Library Module Type Information (Doc ID 1020342.1)            34 The last installed 8U multi-media module with drives in the back.
  Total number of PTPs           0
  Total number of CAPs           2
  Total number of CAP cells      13
  Total number of storage cells  129
  Total number of reserved cells 0
  Total number of tape drives    6
   0,1,1,9
   0,1,2,9
   0,2,1,9
   0,2,2,9
   0,2,3,9
   0,2,4,9
  Total number of empty storage cells 129
  Total number of restricted cells    129

Host Interface Configuration:
Interface Type: FIBRE2GBit
OK
SERVICE>> license print
Sequence Feature Name Feature Value Assigned
-------- ------------ ------------- --------
   99001     Capacity   LimitedBase      Yes
   99002     Capacity      FullBase      Yes
   99003     Capacity       FullDEM      Yes

                         Using
Module   Module Capacity Licenses
------ ----------------- --------
     1     Full Capacity    99001
                            99002

     2     Full Capacity    99003

     3              None      000

     4              None      000

     5              None      000


  129 Cells are Licensed
    0 Cells are Unlicensed
  129 Cells Total are possible
OK
SERVICE>> drive all
Found the following drives:                                                   6 drives total.  4 are LTO and 2 are SDLT drives.

Drive Address:  0,1,1,9
Current Drive Info:
  Drive Type: HpUltrium3
  Serial Number: HU10640TCB
  Interface Type: Fibre
  Firmware Version: L29S/008.753
  Vendor: HP      
  Tape Interface Level: n/a

Drive Address:  0,1,2,9
Current Drive Info:
  Drive Type: HpUltrium3
  Serial Number: MXP0933FH1
  Interface Type: Fibre
  Firmware Version: M66S/011.908
  Vendor: HP      
  Tape Interface Level: n/a

Drive Address:  0,2,1,9
Current Drive Info:
  Drive Type: HpUltrium3
  Serial Number: HU10748CYN
  Interface Type: Fibre
  Firmware Version: M66S/011.908
  Vendor: HP      
  Tape Interface Level: n/a

Drive Address:  0,2,2,9
Current Drive Info:
  Drive Type: HpUltrium3
  Serial Number: MXP07455C0
  Interface Type: Fibre
  Firmware Version: L6HS/012.859
  Vendor: HP      
  Tape Interface Level: n/a

Drive Address:  0,2,3,9
Current Drive Info:
  Drive Type: QuantSDLT320
  Serial Number: RBF34Y5311      
  Interface Type: SCSI
  Firmware Version: 87
  Vendor: Quantum
  Tape Interface Level: n/a

Drive Address:  0,2,4,9
Current Drive Info:
  Drive Type: QuantSDLT320
  Serial Number: RBF34Y5488      
  Interface Type: SCSI
  Firmware Version: 87
  Vendor: Quantum
  Tape Interface Level: n/a

OK
SERVICE>> date print
Date:  02/13/2013
OK
SERVICE>> time print
Time:  14:24:00
OK
SERVICE>> network print
Network Configuration
  Machine Network Name: up185alyn
  IP Address:           10.16.161.131
  Subnet Mask:          255.255.252.0
  MAC Address:          00.10.4F.07.7E.87
  Gateway:(optional)    10.16.160.1
OK
SERVICE>>