![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1528957.1 : Fujitsu M10-1/M10-4/M10-4S - How to Remove and Replace a Power Supply unit in a PCI Expansion Unit
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential). Applies to:Fujitsu M10-4S - Version All Versions and laterFujitsu M10 PCI Expansion Unit - Version All Versions and later Fujitsu M10-1 - Version All Versions and later Fujitsu M10-4 - Version All Versions and later Information in this document applies to any platform. GoalHow to remove and replace a Power Supply unit in a PCI Expansion Unit
SolutionDISPATCH INSTRUCTIONS Before replacing the FRU make sure the Customer has done the Preliminary steps before FRU replacement in a PCI Expansion Unit: Doc Id. 1528544.1
Note for Active/hot maintenance Execute ioxadm command to stop the Power Supply unit under maintenance. In the following example, the PSU#0 of PCIBOX#12B4 is specified. XSCF> ioxadm -f poweroff PCIBOX#12B4/PSU#0 1. Push the lever of the power supply unit under maintenance to release the lock and pull out the PS. PSU#0 is the bottom PS and PSU#1 is the top PS For Active/hot maintenance the Power Supply unit under maintenance must be powered on. In the following example, the PSU#0 of PCIBOX#12B4 is specified. XSCF> ioxadm poweron PCIBOX#12B4/PSU#0 Confirm that there is no problem after the maintenance is complete.
Attachments This solution has no attachment |
||||||||||||||||
|