Asset ID: |
1-71-1528949.1 |
Update Date: | 2016-08-01 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1528949.1
:
Fujitsu M10 PCI Expansion Unit - How to remove and replace a PCI Expansion Unit Link cable
Related Items |
- Fujitsu M10-1
- Fujitsu M10-4S
- Fujitsu M10-4
- Fujitsu M10 PCI Expansion Unit
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Fujitsu M10-1 - Version All Versions and later
Fujitsu M10-4 - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
Fujitsu M10 PCI Expansion Unit - Version All Versions and later
Information in this document applies to any platform.
Goal
How to remove and replace a PCI Expansion Unit Link cable
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1528949.1
********************************************************************************
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Engineer should be M10 product trained
TASK COMPLEXITY: 2
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
A PCI Expansion Unit Link cable has Failed
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
A data backup is not a pre-requisite
Before replacing the FRU make sure the Customer has done the Preliminary steps before FRU replacement in a PCI Expansion Unit: Doc Id. 1528544.1
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Note Link Cables are replaced in pairs. The Link Cables are the top 2 cables on the Link Card.
1. Remove the 2 Link Cables
2. Replace the 2 Link Cables
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
The Customer needs to restore the system to service by following the steps in the Preliminary steps before FRU replacement in a PCI Expansion Unit: Doc Id. 1528544.1
PARTS NOTE:
REFERENCE INFORMATION:
Service Manual - http://docs.oracle.com/cd/E38160_01