Goal
Fix
References


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Fujitsu M10-4 - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
Fujitsu M10 PCI Expansion Unit - Version All Versions and later
Fujitsu M10-1 - Version All Versions and later
Information in this document applies to any platform.

Goal

How to remove and replace an I/O board in a PCI Expansion Unit

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1528918.1
********************************************************************************

 

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:
Engineer should be M10 product trained

TASK COMPLEXITY: 3

TIME ESTIMATE: 60 minutes


FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:
I/O board in a PCI Expansion Unit has Failed

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?

A data backup is not a pre-requisite

Before replacing the FRU make sure the Customer has done the Preliminary steps before FRU replacement in a PCI Expansion Unit: Doc Id. 1528544.1     

 


WHAT ACTION DOES THE ENGINEER NEED TO TAKE:


  1.   Remove the power cords from the PCI Expansion Unit
  2.   Pull out the following components halfway.
            a. Power supply units
            b. PCI Express (PCIe) card cassett
  3.   Remove the front cover.
  4.   Remove all the fan units.
  5.   Loosen the two screws for the PCI tray and pull out the PCI tray slightly.
  6.   Hold the PCI tray with both hands and carefully remove it from the cabinet
  7.   Remove the six cables connected to the I/O board.
  8.   Loosen the two screws for the I/O board at the back of the board
  9.   Hold and slide the guide of the I/O board toward the rear side of the cabinet to remove the board.
 10.  Install the I/O board on the PCI tray.
 11.  Hold the PCI tray with both hands and carefully slid it into the cabinet
 12.  Tighten the two screws for the PCI tray
 13.  Install the removed components and those pulled half way out
 14.  Restore the power to the PCI Expansion Unit



OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:


The Customer needs to restore the system to service by following the steps in the Preliminary steps before FRU replacement in a PCI Expansion Unit: Doc Id. 1528544.1

PARTS NOTE:

REFERENCE INFORMATION:

Service Manual - http://docs.oracle.com/cd/E38160_01