Asset ID: |
1-71-1528590.1 |
Update Date: | 2016-08-01 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1528590.1
:
Fujitsu M10 PCI Expansion Unit - How to Remove and Replace a Fan Unit in a PCI Expansion Unit
Related Items |
- Fujitsu M10-1
- Fujitsu M10-4S
- Fujitsu M10-4
- Fujitsu M10 PCI Expansion Unit
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Fujitsu M10-1 - Version All Versions and later
Fujitsu M10-4 - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
Fujitsu M10 PCI Expansion Unit - Version All Versions and later
Information in this document applies to any platform.
Goal
How to remove and replace a Fan Unit in a PCI Expansion Unit
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1528590.1
********************************************************************************
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Engineer should be M10 product trained
TASK COMPLEXITY: 2
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
Fan Unit in a PCI Expansion Unit has Failed
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
A data backup is not a pre-requisite
Before replacing the FRU make sure the Customer has done the Preliminary steps before FRU replacement in a PCI Expansion Unit: Doc Id. 1528544.1
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Note for Active/hot maintenance Execute the ioxadm command to stop the Fan Unit under maintenance. In the following example, FAN#0 in PCIBOX#12B4 is specified.
XSCF> ioxadm poweroff PCIBOX#12B4/FAN#0
1. Remove the front cover
2. Press the handle of the Fan Unit under maintenance to the left side and remove the Fan Unit from the slot. Fan Units are labeled 0, 1 and 2 with 0 being on the left
3. Insert the replacement Fan Unit in the slot
Note for Active/hot maintenance use the ioxadm command to power on the Fan Unit under maintenance. In the following example, the FAN#0 of PCIBOX#12B4 is specified.
XSCF> ioxadm poweron PCIBOX#12B4/FAN#0
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
The Customer needs to restore the system to service by following the steps in the Preliminary steps before FRU replacement in a PCI Expansion Unit: Doc Id. 1528544.1
PARTS NOTE:
REFERENCE INFORMATION:
Service Manual - http://docs.oracle.com/cd/E38160_01
References