Asset ID: |
1-71-1527648.1 |
Update Date: | 2017-03-27 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1527648.1
:
How to Remove and Replace a M10-4/M10-4S Memory DIMM
Related Items |
- Fujitsu M10-4S
- Fujitsu M10-4
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Created from <SR HOW>
Applies to:
Fujitsu M10-4 - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a M10-4/M10-4S Memory DIMM
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1527648.1
********************************************************************************
Solution
DISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Engineer should be M10-4/M10-4S product trained
TIME ESTIMATE: 50 mins
TASK COMPLEXITY: 4
FIELD ENGINEER/ADM
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:
Please make sure the maintenance-target cabinet is in the correct state before beginning the physical replacement.
See Doc Id. 1526831.1
WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:
Caution - Use proper ESD grounding techniques when handling components.
1. The customer should conduct an orderly shutdown of system software.
2. Power off all physical partitions to stop the entire system before physically removing components
3. Check that the POWER LEDs on all cabinets composing the system is off.
4. For M10-4S systems in a building block configuration:
Release the maintenance-target chassis by executing the replacefru command operation of the XSCF firmware and following the maintenance menu prompts.
XSCF> replacefru
5. Remove all power cords from the PSU backplane unit of the maintenance-target cabinet.
6. Remove the corresponding CPU Memory Unit
7. Replace the DIMM
8. Install the CPU Memory Unit
9. Connect all power cords to the PSU backplane unit of the maintenance-target cabinet.
10. For M10-4S systems in a building block configuration:
Incorporate the maintenance-target chassis by returning to the replacefru command operation of the XSCF firmware and following the maintenance menu prompts.
11. Confirm that there is no problem with the memory after the maintenance
XSCF> showstatus
XSCF> showhardconf -M
12. Start the system.
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO
RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Check for all the domains are up and running fine
REFERENCE INFORMATION:
Service Manual - http://www.fujitsu.com/downloads/SPARCS/manuals/en/c120-e682-11en.pdf
Attachments
This solution has no attachment