Asset ID: |
1-71-1526969.1 |
Update Date: | 2014-04-04 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1526969.1
:
Sun Storage[TM]2540 Multipath Software Compatibility Matrix
Related Categories |
- PLA-Support>Sun Systems>DISK>Arrays>SN-DK: ST25xx
|
In this Document
Applies to:
Sun Storage 2540 Array - Version Not Applicable and later
Information in this document applies to any platform.
Goal
This article documents various multipath/failover software and their compatibility with Sun Storage 2540 arrays.
Solution
Please check the rightmost column "Whom To Contact". If you know or suspect your problem is related to a specific component, please be sure to engage the appropriate support center to START troubleshooting.
OS |
Multipath Software |
Minimum Version |
Latest Version |
Minimum Firmware Supported |
Latest Firmware Supported |
Download Location(latest) |
Host Type Setting |
Install/Config Guide |
Notes |
Whom To Contact |
Solaris 9 |
STMS/MPxIO |
SFK 4.4.9 113039-19
|
SFK 4.4.15(Solaris 9) |
06.17.52.10 |
Current |
MyOracleSupport |
Solaris with MPxIO |
Install Config
|
Internal Only:
SeeSAN/Switch page. Consider using SFKCHECK against explorer
|
Oracle |
Solaris 10 |
STMS/MPxIO |
Solaris 10 U3
RequiredPatches
118833-36 118855-36(x86) 120011-14 120012-14(x86) 127127-11 127128-11(x86)
|
Latet Solaris Update |
06.17.52.10 |
Current |
Distributed via kernel update. |
Solaris with MPxIO |
Solaris 10 SAN config Solaris 10 Storage Multipathing Admin
|
Internal Only:
SeeSAN/Switch page. Consider using SFKCHECK against explorer
|
Oracle |
Solaris 9,10 with DMP |
DMP |
4.1MP2 |
6.0 |
06.17.52.10 |
Current |
ASL |
Solaris with MPxIO (5.x and above)
Solaris with Veritas DMP or other (3.x and 4.x)
|
Doc |
Refer "TECHNOTE" asociated with each ASL for details on install/configure |
Symantec |
Windows 2003 Clustered / Non-Clustered |
MPIO |
01.03.0302.0215 |
01.03.0302.0609 |
06.17.52.10 |
Current |
MyOracleSupprt |
Windows 2000/Server 2003 Clustered / Non Clustered |
Install/Configure Guide |
Support for RDAC on Windows stops at 6.60 firmware. You must use MPIO for 7.10 and above |
Microsoft** |
Windows with DMP |
DMP |
5.0 |
6.0 |
06.17.52.10 |
Current |
ASL |
Windows 2000/Server 2003 non-clustered(with Veritas DMP) |
Doc |
Refer "TECHNOTE" asociated with each ASL for details on install/configure |
Symantec* |
Windows 2008, 2008 R2 Clustered / Non-Clustered |
MPIO |
01.03.0302.0215 |
01.03.0302.0609 |
07.35.44.10 |
Current |
MyOracleSupprt |
Windows 2000/Server 2003 Clustered/Non Clustered |
Install/Configure Guide |
|
Microsoft** |
RHEL 3.x/4.x, SUSE 9/10 |
RDAC/MPP |
09.03.0B02.0214 |
09.03.0B02.0439 |
06.17.52.10 |
Current |
MyOracleSupport |
Linux |
Guide |
|
Oracle |
RHEL5 U1 to U8/RHEL6.0 to U3/ SLES 10SP1 to SP4/SLES11.0,SLES11 SP1 & SP2 |
RDAC/MPP |
09.02.C2.06 |
09.03.0C02.0642 |
06.17.52.10 |
Current |
MyOracleSupport |
Linux |
Guide |
Oracle Linux(5.3 and above) with the Red Hat compatible kernel is available for all hardware systems considered certified or compatible for the corresponding release of Red Hat Enterprise Linux. |
Oracle |
VMware ESX |
OS Native Multipathing |
3.x |
5.x |
06.17.52.10 |
Current |
Part of ESX |
LINUX |
For host type "Linux" follow VMWARE KB to setup the NVSRAM.
|
Doc |
Oracle |
** - Only DSM(Device Specific Module) related issues are handled by Oracle. For MPIO framework related issues contact Microsoft.
For any queries related to Symantec/Veritas Compatibility with array H/W refer
Symantec HCL. For queries related to Platform/Software compatibility, refer "
Compatibility Lists" under
Symantec Documentation.
Explanation of Windows MPIO Builds
WS32 = All 32-bit processors
WS64 = Intel Itanium 64-bit processors only
WSX64 = Intel XEON 64-bit /AMD 64-bit (Opteron) processors
WS8X64 = Windows 2012/Intel XEON 64-bit /AMD 64-bit (Opteron) processors
Explanation of Linux RDAC builds.
Linux 2.4 Based Kernels - RHEL3 (x9.0x.A2.xx builds) (not supported with 07.xx firmware)
Linux 2.6 Based Kernels - RHEL4, SLES9, SLES10 (09.xx.B2.xx builds) )(09.xx.xB02.xxxx)
Linux 2.6.16.16 Based Kernels - SLES10 SP1 and above (09.xx.C2.xx builds)(09.xx.xC02.xxxx)
Linux 2.6.18 Based Kernels - RHEL5 and above (09.xx.C2.xx builds) )(09.xx.xC02.xxxx)
Internal Only:
If your troubleshooting has isolated a component that you do not support, please use the following table to ensure the SR is routed to the proper group.
Multipath S/W | Whom To Contact |
MPXIO |
Storage Drivers - SN-DK :MPXIO or SN-DK:Storage Drivers |
RDAC/MPP/SUNDAC Plugin** |
Storage Midvol - SN-DK:<Array PLA> |
Veritas DMP |
Symantec* |
Cambex DPF |
Storage Midvol - SN-DK:<Array PLA> |
DMMP |
Respective Linux OS vendor |
MPIO |
Storage Midvol - Only DSM related issues handled by MIDVOL. MPIO framework related issues to be directed to Microsoft. |
VMWARE NMP |
VMWARE |
DMMP/Unbreakable Linux |
Oracle Linux - |
53xx NAS |
SN-DK:SE5xxx NAS |
* - All Oracle support for Symantec's Veritas Volume Manager will end in December 2012.
** - To download older version of RDAC other than listed in the matrix use
USR_Archive (Internal only)
Attachments
This solution has no attachment