Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1525519.1
Update Date:2017-04-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1525519.1 :   How to Remove and Replace a SPARC T5-2 Fan Board  


Related Items
  • SPARC T5-2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU part

Applies to:

SPARC T5-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Replace a SPARC T5-2 Fan Board

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1525519.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:(IS A SITE ENGINEER AVAILABLE?)
SPARC T5-2 product and field service training.

Time Estimate: 60 minutes

Task Complexity: 2

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS

PROBLEM OVERVIEW: SPARC T5-2 Server, Fan Board replacing.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
  

ESD Caution:

  • Circuit boards and drives contain electronic components that are extremely sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work environment can destroy the components located on these boards. Do not touch the components along their connector edges.
  • Use a Antistatic Wrist strap. Attach one end of the strap to your wrist and the other end to the chassis, depending on what type of strap you use, with the adhesive end or the metal plug.
  • Use an Antistatic Mat. Place ESD-sensitive components such as motherboards, memory, and other PCBs on an antistatic mat
  

 

  
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
  

This is a cold service procedure that must be performed by qualified service personnel. The system must be completely powered down before performing this procedure.

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:

Prepare for servicing:
    a. Attach an antistatic wrist strap.
    b. Power off the server and unplug power cords from the power supplies.
    c. Extend the server to the maintenance position.
    d. Remove the top cover.


Removing the Fan Board

1. Remove all fan modules.
2. Remove all memory risers.
3. Disconnect any cables plugged into the USB or video connectors on the front of the server.
4. Remove the fan board by completing the following tasks:
    a. Loosen the three captive screws connecting the front memory riser guide to the motherboard.
    b. Remove the two screws on each side of the outside of the chassis that hold the fan board in place and unplug the fan board and power cables from motherboard.
    c. Remove the front memory riser guide by pulling it up and out of the chassis.
    d. Pull the fan board back and out of chassis (The circuit board and the fan holder portions of the fan board should remain together).


Installing the Fan Board

1. Unpack the replacement fan board unit and place it on an antistatic mat.
2. Remove the fan board cable and power cables from the faulty fan board and plug the cables into the fan board on the replacement fan board unit.
3. Reinstall the fan board unit by completing the following tasks:
    a. Insert the fan board into the chassis, moving it down and toward the front.
    b. Reposition the front memory riser guide, routing the fan board and power cable through the riser guide.
    c. Plug the fan board cable and power cable into the connectors on the motherboard.
    d. Secure the fan board by reinserting and tightening the two screws on each side of the outside of the chassis.
    e. Tighten the three captive screws to hold the front memory riser guide in place.
4. Reinstall all fan modules.
5. Reinstall all memory risers.
6. Return the server to operation:
    a. Install the top cover.
    b. Return the server to the normal rack position.
    c. Reinstall the power cords to the power supplies and power on the server.

NOTE: The product serial number used for service entitlement and warranty coverage might need to be reprogrammed on the fan board by authorized service personnel with the correct product serial number located on the chassis EZ label. Refer to doc 1280913.1 for the procedure to update the product serial number.


OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE FE/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
   * If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:

https://support.oracle.com/handbook_partner/Systems/SPARC_T5_2/components.html



REFERENCE INFORMATION:

SPARC T5-2 Service Manual
http://docs.oracle.com/cd/E28853_01/html/E28856/index.html


Oracle Integrated Lights Out Manager 3.2 Documentation
http://docs.oracle.com/cd/E37444_01/


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.