Solution Type  Technical Instruction Sure

Solution  1521779.1 :   How To Remove a RTS in a Sun Fire 4800, 4810, 6800, E4900, and E6900 Systems:ATR:1521779.1:2  


Related Items
  • Sun Fire 6800 Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire E6900 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Created from <SR 3-6678183592>

Applies to:

Sun Fire E4900 Server - Version All Versions and later
Sun Fire 4800 Server - Version Not Applicable and later
Sun Fire 4810 Server - Version All Versions and later
Sun Fire 6800 Server - Version All Versions and later
Sun Fire E6900 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

How To Remove a RTS in a Sun Fire 4800, 4810, 6800, E4900, and E6900 Servers


******************************************************************************

To report errors or request improvements on this procedure,

please go to http://support.us.oracle.com and put a comment on Doc ID: 1521779.1

******************************************************************************

 

Solution

DISPATCH INSTRUCTIONS


WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:

Sun Fire 4800/6800,E4900/E6900 Product Knowledge, and General hardware replacement experience.

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 2

FIELD ENGINEER INSTRUCTIONS:


PROBLEM OVERVIEW:

Redundant Transfer Switch (RTS) Failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Follow standard ESD procedures to avoid Electrostatic Discharge

Replacing the RTS Modules

1. For systems with redundant RTS modules, skip to Step 3.

2. For systems with non-redundant RTS modules, power off the system.

    Refer to the Sun Fire Midrange Systems Platform Administration Manual for complete procedures for powering off the system.

3. Power off the RTS module that is to be replaced

4. Power off the wall circuit breaker connected to the RTS module that is to be replaced.

5. Remove the power cord from the RTS module that is to be replaced.

6. Loosen the screw on the bottom of the RTS module.

7. Pull the module straight out.

8. Install the replacement unit by reversing Step 1 through Step 7.

Ensure proper engagement of the connector in the rear of the module when inserting

the replacement module into the RTU.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

REFERENCE INFORMATION:

Replacement procedures are documented in the Service Manuals:

* Sun Fire 3800/4800/4810/6800 Manual (http://download.oracle.com/docs/cd/E19095-01/sf3800.srvr/805-7363-15/805-7363-15.pdf).

* Sun Fire 4900/E6900 Manual (http://download.oracle.com/docs/cd/E19095-01/sfe4900.srvr/817-4120-13/817-4120-13.pdf).

 