Asset ID: |
1-71-1520354.1 |
Update Date: | 2013-01-25 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1520354.1
:
IPMI Message Handler: BMC Returned Incorrect Response, Expected Netfn 7 Cmd 35, Got Netfn 7 Cmd 1
Related Items |
- Exadata Database Machine X2-2 Qtr Rack
- Oracle Exadata Hardware
|
Related Categories |
- PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
|
Created from <SR 3-4762721921>
Applies to:
Exadata Database Machine X2-2 Qtr Rack - Version All Versions and later
Oracle Exadata Hardware - Version 11.2.0.1 and later
Information in this document applies to any platform.
Goal
Lots of error messages like the following popped up on ILOM Console and also appears in /var/log/message file :
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 2f cmd 24, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 2f cmd 24
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 2f cmd 19, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 2f cmd 19
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 2f cmd 19, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 2f cmd 19
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 2f cmd 19, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 2f cmd 19
Fix
The workaround is to periodically restart the ILOM to clear the error state.
There are 3 main ways to restart the ILOM:
1. Locally from the host OS, via the via the kernel IPMI device driver
# ipmitool bmc reset cold
2. From another host, via network:
# ipmitool -H gpdmcel01-ilom -U root -P bmc reset cold
3. By opening an SSH session directly to the ILOM and issuing:
> reset /SP
Upgrade of ILOM firmware to the latest version will also fix the issue.
Refer <Note 1327022.1> for updating the ILOM firmware manually.
References
<NOTE:1327022.1> - Update Exadata ILOM firmware manually from Storage Cell software patchset
Attachments