Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1520354.1
Update Date:2013-01-25
Keywords:

Solution Type  Technical Instruction Sure

Solution  1520354.1 :   IPMI Message Handler: BMC Returned Incorrect Response, Expected Netfn 7 Cmd 35, Got Netfn 7 Cmd 1  


Related Items
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Oracle Exadata Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-4762721921>

Applies to:

Exadata Database Machine X2-2 Qtr Rack - Version All Versions and later
Oracle Exadata Hardware - Version 11.2.0.1 and later
Information in this document applies to any platform.

Goal

Lots of error messages like the following popped up on ILOM Console and also appears in /var/log/message file :


IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 2f cmd 24, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 2f cmd 24
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 2f cmd 19, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 2f cmd 19
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 2f cmd 19, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 2f cmd 19
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 1, got netfn 7 cmd 35
IPMI message handler: BMC returned incorrect response, expected netfn 2f cmd 19, got netfn 7 cmd 1
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 35, got netfn 2f cmd 19
 

Fix

The workaround is to periodically restart the ILOM to clear the error state.

There are 3 main ways to restart the ILOM:

1. Locally from the host OS, via the via the kernel IPMI device driver
# ipmitool bmc reset cold

2. From another host, via network:
# ipmitool -H gpdmcel01-ilom -U root -P bmc reset cold

3. By opening an SSH session directly to the ILOM and issuing:
> reset /SP

Upgrade of ILOM firmware to the latest version will also fix the issue.

Refer <Note 1327022.1> for updating the ILOM firmware manually.
 

References

<NOTE:1327022.1> - Update Exadata ILOM firmware manually from Storage Cell software patchset

Attachments
This solution has no attachment