Solution  1517537.1 :   Update Master Serial Number On Exadata Machine Using 'DCLI'  


Related Items
  • Exadata X3-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Engineered Systems HW>SN-x64: EXADATA
  •  


Updating  Rack Master Serial Number On Exadata Machines

In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Such Activities are to be addressed Only For Oracle Badged Engineer [TSE / Field Engineer]
Created from <SR 3-6587303704>

Applies to:

Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
All Exadata Systems

Goal

The Goal of this Knowledge Document is to  help customer update Rack Master Serial Number over WEBX /OWC (TSE - Remote Assistance) ,  This would enhance Remote Resolution and Time To Resolve of the Service Request.

 

Solution

 
Verify  that the R-MSN (Rack Master Serial Number)  is set correctly,  using any of the below methods.

1. Manual inspection as mentioned above  Rack's R-MSN is  located on the TOP-LEFT Side wall [viewed from rear ] Inside the rack on the rear of the Chassis.

2. Via ipmi / ilom shell commands

    a.  ipmitool sunoem cli 'show /SP system_identifier

    b.  -> show /SP


If R-MSN is set correctly, then Save it into a file, using the below command.

[root@db01 firstconf]# dcli -l root -g half "ipmitool sunoem cli 'show /SP system_identifier' " > /tmp/show-rack-csn.out

If the R-MSN is incorrect, It can be set  by following the below procedure

Enter the following command on one line, with no break

[root@db01 firstconf]# dcli -l root -g half  "ipmitool sunoem cli' set /SP system_identifier="\"Exadata Database Machine X3-2 1033AK213A\""'" > /tmp/set-rack-csn.out

#Note -g is the group file name

Note that the system_identifier has a 40 character limit,  so if too much text is entered between Machine and the end of the serial number for the R-MSN value,
you will receive a  message stating  "set: invalid property value" error.


Sample Command Usage:

 

[root@u1hiltdb01 ~]# dcli -l root -g dbs_group "ipmitool sunoem cli 'set /SP system_identifier="\"Exadata Database Machine X3-2 AK00066325\""'"