![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1514246.1 : How to replace a Fan (Blower assembly) in a Brocade 48000 Fiber Channel Switch/Director
In this Document
Applies to:Brocade 48000 Director - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalHow to replace a Fan (Blower assembly) in a Brocade 48000 Fiber Channel Switch/Director Solution DISPATCH INSTRUCTIONS Identify the Blower Assembly that needs replacement:
1. Use the screwdriver to loosen the captive screws at the top and bottom of blower assembly.
2. Support the blower assembly from beneath. Push in the top of the handle; then pull out the lower part of the handle to remove the blower assembly. 3. Orient the blower assembly and slide it into the chassis, pushing firmly to ensure that it is seated. 4. Verify that the power LED displays a green light. 5. Push the top of the handle into the recess. 6. Use the screwdriver or your fingers to tighten the captive screws
Verify the Fan (Blower Assembly) LED is steady green, which indicates it is receiving power. Attachments This solution has no attachment |
||||||||||||||
|