![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1509660.1 : How to locate the "Physical Presence" button on SPARC T3-x, T4-x, T5-x, T7-x, S7-x Servers
Applies to:SPARC T4-4 - Version Not Applicable and laterSPARC T3-4 - Version Not Applicable and later SPARC T7-1 - Version All Versions and later SPARC T4-1B - Version Not Applicable and later Netra SPARC T3-1B - Version Not Applicable and later SPARC GoalLocate the "Physical Presence" button on a SPARC T3-x, T4-x, T5-x, T7-x, S7-x Servers SolutionThe "Physical Presence" button locations by server are: T3-x systems - SPARC T3-1 : rear, pin/hole between net3 and usb0 - see attachment (red circle): SPARC_T3-1_rear_zoom.jpg - SPARC T3-2 : rear, pin/hole between nm card/xai slot and net0 - see attachment (red circle): SPARC_T3-2_rear_zoom.jpg - SPARC T3-4 : rear, button on rio between ok/service led and usb1 - see attachment (red circle): SPARC_T3-4_rear_zoom.jpg - SPARC T3-1B : front, locator button - see attachment (red circle): SPARC_T3-1B_front_zoom.jpg - Netra SPARC T3-1 : rear, pin/hole between net3 and usb0 - see attachment (red circle): Netra_T3_1_rear_zoom.jpg - Netra SPARC T3-1B : front, locator button - see attachment (red circle): Netra_T3-1B_front_zoom.jpg - Netra SPARC T3-1BA: -
T4-x systems - SPARC T4-1 : rear, pin/hole between net3 and usb0 - see attachment (red circle): SPARC_T4_1_rear_zoom.jpg - SPARC T4-2 : rear, pin/hole between nm card/xai slot and net0 - see attachment (red circle): SPARC_T4_2_rear_zoom.jpg - SPARC T4-4 : rear, pin/hole on rio between ok/service led and usb1 - see attachment (red circle): SPARC_T4-4_rear_zoom.jpg - SPARC T4-1B : front, locator button - see attachment (red circle): SPARC_T4-1B_front_zoom.jpg - Netra SPARC T4-1 : rear, pin/hole between net3 and usb0 - see attachment (red circle): Netra_T4_1_rear_zoom.jpg - Netra SPARC T4-2 : rear, pin/hole on left side of video port (hd-15) - see attachment (red circle): Netra_T4_2_rear_zoom.jpg - Netra SPARC T4-1B : front, locator button - see attachment (red circle): Netra_T4_1B_front_zoom.jpg
T5-x systems - SPARC T5-2 : front/rear, locator button - see attachment (red circle): SPARC_T5_2_rear_zoom.jpg - SPARC T5-4 : front/rear, locator button - see attachment (red circle): SPARC_T5_4_rear_zoom.jpg - SPARC T5-8 : front/rear, locator button - see attachment (red circle): SPARC_T5_8_rear_zoom.jpg - SPARC T5-1B : front/rear, locator button - see attachment (red circle): SPARC_T5_1B_front_zoom.jpg - Netra SPARC T5-1B : front, locator button - see attachment (red circle): Netra_T5_1B_front_zoom.jpg
T7-x systems - SPARC T7-1 : front/rear, locator button - see attachment (red circle): SPARC_T7_1_front_zoom.jpg, SPARC_T7_1_rear_zoom.jpg - SPARC T7-2 : front/rear, locator button - see attachment (red circle): SPARC_T7_2_front_zoom.jpg, SPARC_T7_2_rear_zoom.jpg - SPARC T7-4 : front/rear, locator button - see attachment (red circle): SPARC_T7_4_front_zoom.jpg, SPARC_T7_4_rear_zoom.jpg S7-x systems
- SPARC S7-2 : front/rear, locator button - see attachment (red circle): SPARC_S7_2_front_zoom.jpg, SPARC_S7_2_rear_zoom.jpg
- SPARC S7-2L : front/rear, locator button - see attachment (red circle): SPARC_S7_2L_front_zoom.jpg, SPARC_S7_2L_rear_zoom.jpg
- Netra SPARC S7-2 : front/rear, locator button - see attachment (red circle): Netra_S7_2_front_zoom.jpg, Netra_S7_2_rear_zoom.jpg
NOTES
- T7-x, S7-x and all platforms forward should use the Locator button (front/rear) as the Physical Presence switch - To perform some procedures documented in the Oracle ILOM core documentation, you must create a serial connection to the server and activate the Physical Presence switch on the server. For information about creating a serial connection, refer to the installation guide for the server. - If the physical presence/locator button is not working and/or can not be located, then as temporary workaround the physical presence check can be disabled: - -> show /SP check_physical_presence - -> set /SP check_physical_presence=false - -> show /SP check_physical_presence and it can be later enabled - -> show /SP check_physical_presence - -> set /SP check_physical_presence=true - -> show /SP check_physical_presence - For more information look at the documents below: - T Series Server Documentation - Oracle Integrated Lights Out Manager (ILOM) 3.x Documentation
Attachments This solution has no attachment |
||||||||||||
|