Solution Type Technical Instruction Sure Solution 1508287.1 : How to replace an SFP in a Brocade 48000 Director Fiber Channel Switch
In this Document
Applies to:Brocade 48000 Director - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalHow to replace an SFP in a Brocade 48000 Director Fiber Channel Switch Solution DISPATCH INSTRUCTIONS The director comes with a transceiver extraction tool and holster. The extraction tool is designed to remove transceivers from port blades where the space is limited. To use the extraction tool, slide the tool on to the bale of the transceiver and pull it out.
Remove the cables from the SFP(s) to be replaced.
To remove an SFP or XFP (FC6-10 blade only) transceiver, pull the bale down and out, sliding the transceiver out of the port blade. To install an SFP or XFP, position one of the transceivers so that the key is oriented correctly to the port. Insert the transceiver into the port until it is firmly seated and the latching mechanism clicks. Transceivers are keyed so that they can only be inserted with the correct orientation. If a transceiver does not slide in easily, ensure that it is correctly oriented. Connect the cables to the transceivers: Orient a cable connector so that the key (the ridge on one side of connector) aligns with the slot in the transceiver, then insert cable into transceiver until latching mechanism clicks. Note: The cable connectors are keyed to ensure correct orientation. If a cable does not install easily, ensure it is correctly oriented. Repeat for the remaining transceivers as required.
Attachments This solution has no attachment |
||||||||||||||
|