Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1507254.1
Update Date:2014-05-06
Keywords:

Solution Type  Technical Instruction Sure

Solution  1507254.1 :   How to replace SFPs in Brocade 200e and 300 switches.  


Related Items
  • Brocade 200E Switch
  •  
  • Brocade 300 Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Brocade 200E Switch - Version All Versions to All Versions [Release All Releases]
Brocade 300 Switch - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 How to replace SFP 

Solution

 DISPATCH INSTRUCTIONS
   WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
   TIME ESTIMATE: 5 minutes
   TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
   PROBLEM OVERVIEW:  An SFP has failed and needs to be replaced
   WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:  NA
   WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Locate the defective SFP
If there is a cable attached press and hold the cable release
Remove the cable from the SFP.
Pull the bail (wire handle) to release the SFP.
Grasping it by the bail, gently but firmly pull the SFP out of the port.

 

Caution
If the SFP you are removing does not have a bail, use a small implement such as a screwdriver to press the black release trigger beneath or above the port. Non-bailed SFPs can be damaged by the removal process and are not recommended. Refer to the Brocade Compatibility Matrix for a list of supported SFPs and devices

Making sure that the bail (wire handle) is in the unlocked position, place the SFP in the correctly oriented position on the port.
Slide the SFP into the port until you feel it click into place; then close the bail.
Reattach any cables that had previously been disconnected.
Check the LEDs to verify connectivity via link light.

 


Note
Each SFP has a 10-pad gold-plated PCB-edge connector on the bottom. The correct position to insert an SFP into the upper row of ports is with the gold edge down. The correct position to insert an SFP into the lower row of ports is with the gold edge up.

Note
The Brocade 300 supports only Brocade-branded SFPs. If you use an unqualified SFP, the switchShow command output shows the port in a Mod_Inv state. Fabric OS also logs the issue in the system error log.

OBTAIN CUSTOMER ACCEPTANCE
   WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?  None

 