Solution Type Technical Instruction Sure Solution 1507020.1 : How to replace an SFP in a Brocade 3900 4100 4900 5000 Fiber Channel Switch
In this Document
Applies to:Brocade 5000 Switch - Version All Versions to All Versions [Release All Releases]Brocade 4100 Switch - Version All Versions to All Versions [Release All Releases] Brocade 4900 Switch - Version All Versions to All Versions [Release All Releases] Brocade 3900 Switch - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalHow to replace an SFP in a Brocade 3900 4100 4900 5000 Fiber Channel Switch Solution DISPATCH INSTRUCTIONS Identify switch port(s) with faulty SFP(s). Remove the cables from the SFP(s) to be replaced. Pull the bail (wire handle) to release the transceiver. Grasp the bail, and gently but firmly pull the transceiver out of the port. Position a transceiver (SFP) so that it is oriented correctly and insert into a port until it is firmly seated and the latching mechanism clicks. Orient a cable connector so that the key (the ridge on one side of connector) aligns with the slot in the transceiver, then insert cable into transceiver until latching mechanism clicks. Note: The cable connectors are keyed to ensure correct orientation. If a cable does not install easily, ensure it is correctly oriented. Repeat for the remaining ports as required. Connect the cables to the transceivers.