![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1501642.1 : How to Replace Power Centerplane for Sun Fire 4810 Systems:ATR:1501642.1:3
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers. Applies to:Sun Fire 4810 Server - Version Not Applicable and laterInformation in this document applies to any platform. GoalHow to Replace System Centerplane for Sun Fire 4810 Systems
please go to http://support.us.oracle.com and put a comment on Doc ID: 1501642.1
FixDISPATCH INSTRUCTIONS
1. Halt the Solaris operating environment in each domain and power off the system.
4.At the rear of the system, remove the left five screws of the mounting bracket for 5. At the rear of the system, remove the screws securing the rear screen panel to the system
8. Remove the eight screws securing the bus bar to the backplanes 9. Remove the 36 screws securing the system centerplane to the chassis. 10. Remove the system centerplane carefully from the chassis. 11. Align the power centerplane with the bottom of the chassis, and replace the screws. 12. Secure the bus bar to the centerplane by replacing the eight screws. 13. Replace the three screws securing the protective cover over the bus bar 14. Connect the signal cable to the system centerplane and the power backplane 15. Replace the screws securing the rear screen panel to the system. 16. Replace the five screws securing the left mounting bracket to the cabinet 17. At the front of the system, replace all the power supplies. 18. Make sure that the three power switches on the AC input box are turned on. 19. Power on the system. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES CUSTOMER NEED TO TAKE TO RETURN SYSTEM TO AN OPERATIONAL STATE:
REFERENCE INFORMATION: Replacement procedures are documented in the Service Manuals: * 3800/48x0/6800 Manual http://download.oracle.com/docs/cd/E19095-01/sf3800.srvr/805-7363-15/805-7363-15.pdf * E4900/E6900 Manual http://download.oracle.com/docs/cd/E19095-01/sfe4900.srvr/817-4120-13/817-4120-13.pdf Attachments This solution has no attachment |
||||||||||||||
|