Goal
Solution


Applies to:

Sun Storage 6140 Array - Version All Versions and later
Information in this document applies to any platform.

Goal

 This article documents various multipath/failover software and their compatibility with Sun Storage 6140 arrays.

Solution

 Please check the rightmost column "Whom To Contact". If you know or suspect your problem is related to a specific component, please be sure to engage the appropriate support center to START troubleshooting.

 

OS Multipath Software Minimum Version Latest Version Minimum Firmware Supported Latest Firmware Supported Download Location(latest) Host Type Setting Install/Config Guide Notes Whom To Contact
Solaris 8 STMS/MPxIO SFK 4.4.9 SFK 4.4.13 06.16.81.10 07.50.13.10 MyOracleSupport Solaris with MPxIO

Install
Config

Internal Only :

SeeSAN/Switch page. Consider using SFKCHECK against explorer

Oracle
Solaris 9 STMS/MPxIO SFK 4.4.9 SFK 4.4.15(Solaris 9) 06.16.81.10 Current MyOracleSupport Solaris with MPxIO

Install
Config

 

Internal Only:

SeeSAN/Switch page. Consider using SFKCHECK against explorer

 

Oracle
Solaris 10 SPARC STMS/MPxIO 118833-16

118833-36
120011-14
127127-11
137137-09
139555-08
140919-03

06.16.81.10 Current Distributed via kernel update Solaris with MPxIO

Solaris 10 SAN config
Solaris 10 Storage Multipathing Admin

 

Internal Only:

SeeSAN/Switch page. Consider using SFKCHECK against explorer

 

Oracle
Solaris 10 x86/64 STMS/MPxIO 118855-14

118855-36
120012-14
127128-11
137138-09
139556-08
140920-03

06.16.81.10 Current Distributed via kernel update Solaris with MPxIO

Solaris 10 SAN config
Solaris 10 Storage Multipathing Admin

 

Internal Only:

See SAN/Switch page . Consider using SFKCHECK aganist explorer

 

Oracle
Solaris 8,9,10 with DMP DMP 4.1 6.0 06.16.81.10 Current ASL Solaris with DMP Doc Refer "TECHNOTE" asociated with each ASL for details on install/configure Symantec*
Windows 2000 Non-Clustered RDAC/MPIO 09.01.32.30(RDAC) 01.03.0302.0609(MPIO) 06.16.81.10 07.15.11.11 MyOracleSupprt Windows 2000/Server 2003 Non Clustered Install/Configure Guide Support for RDAC on Windows stops at 6.60 firmware. You must use MPIO for 7.10 and above Microsoft**
Windows 2003 Non-Clustered RDAC/MPIO 09.01.32.30(RDAC) 01.03.0302.0609(MPIO) 06.16.81.10 Current MyOracleSupprt Windows 2000/Server 2003 Non Clustered Install/Configure Guide Support for RDAC on Windows stops at 6.60 firmware. You must use MPIO for 7.10 and above Microsoft**
Windows MSCS Cluster RDAC/MPIO 09.01.32.30(RDAC) 01.03.0302.0609(MPIO) 06.16.81.10 Current MyOracleSupprt Windows 2000/Server 20003 Clustered Install/Configure Guide Assumes single node support is followed for base os Microsoft**
Windows 2000/2003 Non-Clustered with DMP DMP 5.0 6.0 06.16.81.10 Current ASL Windows 2000/Server 2003 non-clustered(with Veritas DMP) Doc Refer "TECHNOTE" asociated with each ASL for details on install/configure Symantec*
Windows 2003 Clustered with DMP DMP 5.0 6.0 06.16.81.10 Current ASL Windows Server 2003 clustered(with Veritas DMP) Doc Refer "TECHNOTE" asociated with each ASL for details on install/configure Symantec*
Windows 2008, R2 MPIO 01.03.0302.0013 01.03.0302.0609 06.60.11.10 Current MyOracleSupprt Windows 2000/Server 2003 Install/Configure Guide   Microsoft**
AIX 5.2/5.3 SUNdac Plugin 5.2.0.16 5.2.0.16 06.16.81.10 Current MyOracleSupport AIX Install Guide is ncluded in the patch   Oracle
AIX 6.1/5.3/5/2 CAMBEX 5.2.0.63 6.1.0.63 07.50.08.10 Current

AIX-6.1
AIX-5.3
AIX-5.2

AIX(failover) Install/Configure guide is included within the patch/package.


Customer who purchased Cambex DPF from Oracle should contact Oracle otherwise contact the respective vendor.

To purchase a new license or to transfer existing one please use below link,

CAMBEX DPF LICENSE

Oracle
AIX with DMP DMP 4.0MP4 6.0 06.16.81.10 Current ASL AIX with DMP Doc Refer "TECHNOTE" asociated with each ASL for details on install/configure. Symantec*
Red Hat 3/SUSE 8 RDAC/MPP 09.00.A2.19 09.00.A2.19 06.16.81.10 07.10.25.10   Linux Guide   Oracle
Red Hat 4/SuSE 9/SUSE 10 RDAC/MPP 09.01.B2.31 09.03.0B02.0439 06.16.81.10 Current MyOracleSupport Linux Guide   Oracle
RHEL 5U2 to U7/SUSE 10 SP1 to SP4 /RHEL6.0, U1/SLES 11, 11SP1 RDAC/MPP 09.02.C2.06 09.03.0C02.0642 06.16.81.10 Current MyOracleSupport Linux Guide Oracle Linux(5.3 and above) with the Red Hat compatible kernel is available for all hardware systems considered certified or compatible for the corresponding release of Red Hat Enterprise Linux. Oracle
SUSE 11 RDAC/MPP 09.03.0C02.0439 09.03.0C02.0642 07.60.xx.xx Current MyOracleSupport  Linux Guide    Oracle
Red Hat/SUSE with DMP DMP 4.1 6.0 06.16.81.10 Current ASL Linux with DMP Doc Refer "TECHNOTE" asociated with each ASL for details on install/configure Symantec*
HPUX Veritas DMP 4.1 4.1 06.16.81.10 Current ASL HP-UX Doc Refer "TECHNOTE" asociated with each ASL for details on install/configure Symantec*
VMware ESX OS Native Multipathing 3.0 5.x 06.16.81.10 Current Part of ESX

LINUX or

VMWARE ->(7.50 and above)

 

Internal Only:

For host type "Linux" follow below doc to setup the NVSRAM.

VMware 3.5 NVSRAM setup

 

 Doc Vmware
53xx NAS Gateway Attachment NAS Gateway FCS 4.22M1B165 06.16.81.10 06.60.11.11 Download Sun StorageTek 53xx NAS Gateway Gateway Setup   Oracle

 

 

* - Oracle support for Veritas Volume Manager ended in December 2012. Contact Symantec for any issues related to VXVM and DMP.

** - Only DSM(Device Specific Module) related issues are handled by Oracle. For MPIO framework related issues contact Microsoft.

 

For any queries related to Symantec/Veritas Compatibility with array H/W refer Symantec HCL. For queries related to Platform/Software compatibility, refer "Compatibility Lists" under  Symantec Documentation.

 

Explanation of Windows MPIO Builds

WS32 = All 32-bit processors
WS64 = Intel Itanium 64-bit processors only
WSX64 = Intel XEON 64-bit /AMD 64-bit (Opteron) processors
WS8X64 = Windows 2012/Intel XEON 64-bit /AMD 64-bit (Opteron) processors

 

Explanation of Linux RDAC builds.

Linux 2.4 Based Kernels - RHEL3 (x9.0x.A2.xx builds) (not supported with 07.xx firmware)
Linux 2.6 Based Kernels - RHEL4, SLES9, SLES10 (09.xx.B2.xx builds) )(09.xx.xB02.xxxx)
Linux 2.6.16.16 Based Kernels - SLES10 SP1 and above (09.xx.C2.xx builds)(09.xx.xC02.xxxx)
Linux 2.6.18 Based Kernels - RHEL5 and above (09.xx.C2.xx builds) )(09.xx.xC02.xxxx)

 

Internal Only:

If your troubleshooting has isolated a component that you do not support, please use the following table to ensure the SR is routed to the proper group.

Multipath S/WWhom To Contact
MPXIO Storage Drivers - SN-DK :MPXIO or SN-DK:Storage Drivers
RDAC/MPP/SUNDAC Plugin** Storage Midvol  - SN-DK:<Array PLA>
Veritas DMP Symantec*
Cambex DPF Storage Midvol - SN-DK:<Array PLA>
DMMP Respective Linux OS vendor
MPIO Storage Midvol - Only DSM related issues handled by MIDVOL. MPIO framework related issues to be directed to Microsoft.
VMWARE NMP  VMWARE
DMMP/Unbreakable Linux Oracle Linux -
53xx NAS SN-DK:SE5xxx NAS

 

* - All Oracle support for Symantec's Veritas Volume Manager ended in December 2012.
** - To download older version of RDAC other than listed in the matrix use USR_Archive (Internal only)

 

Do you still have questions?  You can use My Oracle Support Communities.  Communities put you in touch with industry professionals like yourself.  They are monitored by Oracle support engineers, so you can expect reliable and correct answers.  Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.

 