Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1490121.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1490121.1 :   How to Remove and Replace Netra 210 Single Fan Tray:ATR:1490121.1:0  


Related Items
  • Sun Netra 210 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Netra 210 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 Netra 210 - How to Remove and Replace Single Fan Tray

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED:

No special skills required, Customer Replaceable Unit (CRU) procedure


TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW: Fault Single Fan Tray

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

There is ONLY a CRU part number for the Fan Tray. However, the service manual explains the procedure to replace individual Fan 0-3 and Fan 4-5.

WHAT ACTIONS ARE REQUIRED:

Replacing Fans 0-3

Removing Fans 0-3
1. Power off the server, remove the server from the rack, and remove the top cover and airduct.

2. Locate the fans. Fans 0-3 are located at the center front of the chassis.

3. Disconnect the fan cable according to the following table.

Fans 0-3 and Their Connectors
Fan Connector
Fan 0 J1, adapter board
Fan 1 J2, adapter board
Fan 2 F2, system board
Fan 3 F3, system board

Note – Remove the SAS cables from J7 of the SAS IF board before removing the fan cable from F3.

4. Lift the fan up and out of its bracket.

5. Set the fan aside on an antistatic mat.

6. Repeat Step 3 to Step 5 for each fan to be removed.

Caution – Do not power on the server without the fans installed.

7. Replace the fans.

Installing Fans 0-3

1. Locate where the fan installs. Fans 0-3 install at the center front of the chassis.

2. Remove the replacement fan from its shipping container and antistatic packaging.

3. Set the fan down into the bracket.

4. Connect the fan cable to its respective connector.
Use the following table.

Fan Connector
Fan0 J1, adapter board
Fan1 J2, adapter board
Fan2 F2, system board
Fan3 F3, system board

Note – Connect the SAS cables to J7 of the SAS IF board after connecting the fan cable from F3.

5. Install the air duct and top cover, install the server into the rack, power on the server, and verify the installation.

 

Removing Fans 4 and 5

1. Locate the fans.
Fans 4 and 5 are located between the SAS IF assembly and the power supply at the
right front of the chassis.
2. Lift both fans up and out of the bracket.

3. Disconnect the fan cable of the fan to be removed from the power supply:
■ Fan 4 - J7

■ Fan 5 - J5

Disconnecting the Fan Cable

4. Remove the fan and set it aside on an antistatic mat.

5. Repeat Step 4 and Step 5 for each fan to be removed.

Caution – Do not power on the server without the fans installed.

6. Replace fans

Installing Fans 4 and 5

1. Locate where the fans install. Fans 4 and 5 install between the SAS IF assembly and the power supply at the right front of the chassis.

2. If either Fan 4 or Fan 5 is installed, lift it from the bracket.

3. Remove the replacement fan from its shipping container and antistatic packaging.

4. Connect the fan cable to its connector on the power supply.
■ Fan 4 - J7
■ Fan 5 - J5

5. Set both fans down into the bracket.

6. Install the top cover, install the server into the rack, power on the server, and verify the installation.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

If the replacement was a hot swap/plug on a redundant configuration, the system should be operational and need no further work.
If the replacement was in a system with a single power supply, restart software applications per applicable administration guides to resume system operation

PARTS NOTE:

https://support.oracle.com/handbook_private/Systems/Netra_210/components.html

REFERENCE INFORMATION:

Please refer to the Netra 210 Server Service Manual: http://docs.oracle.com/cd/E19102-01/n210.srvr/819-2750-10/819-2750-10.pdf

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback