  Netra 210 - How to Remove and Replace the Battery

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure

TASK COMPLEXITY: 0

TIME ESTIMATE: 50 minutes

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: Battery failure

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTIONS ARE REQUIRED:

The battery used on the Netra 210 server system board is a type CR2032 or compatible equivalent.

Removing the Battery

1. Power off the server, remove the server from the rack, and remove the top cover and airduct.

2. Locate the battery. The battery is located at the left front of the system board.

3. Press the tab at the side of the battery to release it.

4. Lift the battery up and out of the socket.

Caution – Do not power on the server without the battery installed.

Installing the Battery

1. Remove the server from the rack and remove the top cover.

2. Locate where the battery installs. The battery installs at the left front of the system board.

3. Remove the replacement battery from its shipping container and antistatic packaging.

4. Press the battery down into the socket, plus (+) side up.

5. Install the air duct and top cover, install the server into the rack, power on the server, and verify the installation.


WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:


Restart software applications per applicable administration guides to resume system operation.


PARTS NOTE: Include Battery Unit location:

https://support.oracle.com/handbook_private/Systems/Netra_210/components.html


ADDITIONAL COMMENTS:

Please refer to the Netra 210 Server Service Manual: http://docs.oracle.com/cd/E19102-01/n210.srvr/819-2750-10/819-2750-10.pdf

 

 