Solution Type Technical Instruction Sure Solution 1489872.1 : Sun StorageTek CSM200 ESM 7-Segment LED Display Codes
In this Document
Created from <SR 3-6072346761> Applies to:Sun Storage CSM200 Array - Version Not Applicable to Not Applicable [Release N/A]Sun Storage 6140 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 6540 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 6780 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 6580 Array - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. GoalMany of the Oracle Midrange Disk Array products provide for storage expansion with the addition of the CSM200 tray. The CSM200 tray holds up to 16 disk drives as well as its own redundant power, cooling and I/O. The I/O component (Commonly referred to as an "IOM" Input/Output Module or "ESM" External Storage Module) has two seven segment displays. A optimal IOM contains a two digit value in the display. This two digit integer (It may be any value from 00-87, 89-99) is known as the tray ID. The tray id is soft assigned (each tray id needs to be unique in the array) or may be set using Sun Storage Common Array Manager (CAM). When there is a problem with an IOM, the seven segment display will return an alpha-numeric code. This document details the code and its meaning to assist in troubleshooting the problem at hand. FixThe following list explains the meaning of the status code displayed on a CSM200 expansion tray