Goal
Solution
 Removing a PCI Card
 Installing a PCI Card


Applies to:

Sun Netra 210 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

Netra 210 -  How to Remove and Replace PCI Card

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED:

No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0


REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW: Faulty PCI Card


WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:


A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.


WHAT ACTIONS ARE REQUIRED:

The following procedures describe how to remove and install individual PCI cards into the Netra 240 server.

Removing a PCI Card

1.Power off the server.

2.Remove the server cover.

3.Open the rotating service module.

4.Ensure that the server is properly grounded.

5. Completely remove the air duct.

6. Locate the PCI card.

7. Loosen the PCI card thumbscrew at the chassis rear panel.

8. Rotate the PCI card latch clockwise.

9. Lift up on the PCI card retainer knob and slide the retainer forward.

10. Remove the PCI card from the slot.

 

Installing a PCI Card

1. Locate where the PCI card installs. The PCI card installs at the left rear of the chassis.

2. Loosen the PCI card thumbscrew at the chassis rear panel.

3. Rotate the PCI card latch clockwise.

4. If present, remove the filler panel from the chassis rear panel.

5. Lift up on the PCI card retainer knob and slide the retainer forward.

6. Remove the PCI card from its shipping container and antistatic packaging.

7. Install the PCI card into the slot.

8. Rotate the PCI card latch counter-clockwise so that it holds the PCI card in place.

9. Tighten the PCI card thumbscrew at the chassis rear panel.

10. Lift up on the PCI card retainer knob and slide the retainer back to secure the PCI

 

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Bring system back up to a functioning state.
Restart software applications per applicable administration guides to resume system operation.