![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1488814.1 : How to Remove and Replace a Sun Ultra 25/Ultra 45 Workstation Power Supply:ATR:1488814.1:1
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers. Applies to:Sun Ultra 25 Workstation - Version Not Applicable to Not Applicable [Release N/A]Sun Ultra 45 Workstation - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. GoalSun Ultra 25/Ultra 45 Workstation - How to Remove and Replace a Sun Ultra 25 Workstation Power Supply Fix DISPATCH INSTRUCTIONS Sun Ultra 25/Ultra 45 Workstation product training is desirable but not required TIME ESTIMATE: 60 mins TASK COMPLEXITY: 1 WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: Replacing the Power SupplyThis section describes removal and installation of the power supply. Removing the Power Supply1. Power off the system and attach an antistatic wrist strap. Open and position the chassis, and remove the access panel. 2. If necessary, remove any long PCI cards that are blocking the cables. - Place the PCI card on an antistatic mat. 3. Remove the fan tray. 4. Squeeze the power supply connector clip to disconnect the following cables from the motherboard: - P2 power cable on the motherboard (J22) - P1 power cable on the motherboard at (J28) - P5 power supply signal cable on the motherboard (J45) 5. Disconnect the following cables from the hard drive backplane: - P3 hard drive backplane power cable on the hard drive backplane (J2) - Hard drive signal cable to J4 on the hard drive backplane. (This cable also serves as a cable clip over other cables). 6. Turn the captive screw that secures the power supply to the chassis 7. Using the handle, push the power supply out of the back of the chassis. 8. Guide the power cables out of the chassis as you push the power supply out the back of the chassis. - Set the power supply aside on an antistatic mat. Installing the Power Supply1. Remove the new power supply from its package. 2. Align the power supply IEC-320 connector so that the power cord socket is nearest the left rear of the chassis, when viewed from the back. 3. Guide the cables and push the power supply into the chassis opening until the back of the power supply aligns with the back of the chassis. 4. Tighten the captive screw that secures the power supply to the chassis. 5. Connect the following cables: - P1 power cable on the motherboard at (J28) - P2 power cable on the motherboard (J22) - P3 hard drive backplane power cable on the hard drive backplane (J2) - P5 power supply signal cable on the motherboard (J45) - Hard drive signal cable to J4 on the hard drive backplane. (This cable also serves as a cable clip over other cables). 6. Inspect the power supply fasteners to verify that: - The power supply push bar is seated. - The power supply captive screw is tight. 7. Inspect the power supply cabling to verify that: - The three power supply cables are firmly connected to the motherboard at P1, P2, and P5 (J45). - The hard drive backplane power cable is firmly connected at J4. - The hard drive backplane signal cable is securely connected at both ends and is routed over the other cables. 8. Install the fan tray. 9. If you removed any PCI cards, re-install them. 10. Reasemble the workstation. Power on the system, and verify the power supply installation. Restart software applications per applicable administration guides to resume system operation. PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Ultra25/components.html https://support.oracle.com/handbook_private/Systems/Ultra45/components.html REFERENCE INFORMATION: Please refer to the Sun Ultra 25/Ultra 45 Workstation Service and Diagnostics Manual: http://docs.oracle.com/cd/E19127-01/ultra25.ws/819-1892-12/819-1892-12.pdf
Attachments This solution has no attachment |
||||||||||||||||||||
|