![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1488583.1 : SL24/SL48 - Unable To Configure SL24 Tape Drive In Oracle Secure Backup with the Erie HBA (SAS 2)
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL24 Tape Autoloader - Version All Versions and laterSun StorageTek SL48 Tape Library - Version All Versions and later Sun StorageTek SL500 Modular Library System - Version All Versions and later Information in this document applies to any platform. GoalSL24/SL48 - Unable To Configure SL24 Tape Drive In Oracle Secure Backup with the Erie HBA (SAS 2) Assuming the SL24 is not supported with the Erie HBA (SAS 2) and mpt2_sas driver then what HBA / Connectivity would it be supported on Solaris 11? SolutionAny SAS-1 HBA will support the LTO SAS 1/2 tape drives on Solaris 10 and 11. SAS is NOT supported on Solaris 9. Solaris 11 uses the same MPT2 driver that Solaris 10 uses so at this time we do not support the SL24/48 or SL500 libraries with SAS2 drives on a Solaris server with a SAS2 HBA in it. That also holds true for the desktop and rack mount SAS2 tape drives. Provided by Ryan Lucas. Attachments This solution has no attachment |
||||||||||||||
|