Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1488583.1
Update Date:2017-09-25
Keywords:

Solution Type  Technical Instruction Sure

Solution  1488583.1 :   SL24/SL48 - Unable To Configure SL24 Tape Drive In Oracle Secure Backup with the Erie HBA (SAS 2)  


Related Items
  • Sun StorageTek SL48 Tape Library
  •  
  • Sun StorageTek SL500 Modular Library System
  •  
  • Sun StorageTek SL24 Tape Autoloader
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only
Created from <SR 3-6113551701>

Applies to:

Sun StorageTek SL24 Tape Autoloader - Version All Versions and later
Sun StorageTek SL48 Tape Library - Version All Versions and later
Sun StorageTek SL500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

SL24/SL48 - Unable To Configure SL24 Tape Drive In Oracle Secure Backup with the Erie HBA (SAS 2)

Assuming the SL24 is not supported with the Erie HBA (SAS 2) and mpt2_sas driver then what HBA / Connectivity would it be supported on Solaris 11?

Solution

Any SAS-1 HBA will support the LTO SAS 1/2 tape drives on Solaris 10 and 11.  SAS is NOT supported on Solaris 9.

Solaris 11 uses the same MPT2 driver that Solaris 10 uses so at this time we do not support the SL24/48 or SL500 libraries with SAS2 drives on a Solaris server with a SAS2 HBA in it.

That also holds true for the desktop and rack mount SAS2 tape drives.

Provided by Ryan Lucas.



 