![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1488469.1 : How to Remove and Replace a Sun Fire V250 DVD or Optional Tape Drive:ATR:1488469.1:1
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers. Applies to:Sun Fire V250 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalSun Fire V250 - How to Remove and Replace a Sun Fire V250 DVD or Optional Tape Drive Fix DISPATCH INSTRUCTIONS Sun Fire V250 product training is desirable but not required. TIME ESTIMATE: 45 mins TASK COMPLEXITY: 1 WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: DVD-ROM Drive (Tape drive instructions below) Caution – The DVD-ROM drive contains a laser device. Do not attempt to open the DVD-ROM drive’s enclosure or remove a DVD-ROM drive using any procedures other than those contained in this section. To Remove the DVD-ROM Drive 1. Check that no media is present in the DVD-ROM drive. 2. Turn server power off. 3. Open the door. 4. Ensure the server is properly grounded. 5. Unclip the DVD-ROM drive module. 6. Slide the DVD-ROM drive out of the slot. 7. Disconnect the power and data cables. To Replace the DVD-ROM Drive 1. Turn server power off. 2. Open the door. 3. Ensure the server is properly grounded. 4. Connect the power and data cables to the replacement DVD-ROM drive module. 5. Slide the replacement module firmly into its slot. Tape Drive (Optional) The tape drive is located on the server’s front panel. If it is not installed, a blanking plate is fitted in its place. To Remove the Tape Drive 1. Check that no media is present in the tape drive. 2. Turn server power off. 3. Open the door. 4. Ensure the server is properly grounded. 5. Release the tape drive module from the server. 6. Slide the tape drive out of the server’s chassis. 7. Disconnect the power and data cables. To Install a Tape Drive 1. Turn server power off. 2. Open the door. 3. Ensure the server is properly grounded. 4. Remove the blanking plate. (if installed) 5. Attach the power and data cables to the tape drive module. 6. Slide the tape drive firmly into its slot.
Restart software applications per applicable administration guides to resume system operation. PARTS NOTE: https://support.oracle.com/handbook_private/Systems/SunFireV250/components.html REFERENCE INFORMATION: Please refer to the Sun Fire V250 Parts Replacement Manual: http://docs.oracle.com/cd/E19088-01/v250.srvr/817-0901-10/817-0901-10.pdf
Attachments This solution has no attachment |
||||||||||||||
|