Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1488396.1
Update Date:2017-12-13
Keywords:

Solution Type  Technical Instruction Sure

Solution  1488396.1 :   How to Remove and Replace a Sun Fire V250 memory DIMM:ATR:1488396.1:1  


Related Items
  • Sun Fire V250 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Memory Dimms are FRU's as per SSH

Applies to:

Sun Fire V250 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 Sun Fire V250 - How to Remove and Replace a Sun Fire V250 memory DIMM

Solution

 DISPATCH INSTRUCTIONS
   WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:

Sun Fire V250 product training is desirable but not required

   TIME ESTIMATE: 120 mins

   TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
   PROBLEM OVERVIEW: Faulty Memory Dimm

   WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.


   WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

There are four memory module sockets per processor on the server’s system board. Memory is supplied by Sun in paired DIMMS. Ensure that you use the DIMM pairs as supplied and do not mix them.

Memory Configuration Rules

Memory is shipped in matched pairs for use on the Sun Fire V250 server. Use memory only in these matched pairs - do not mix memory modules.
When you install memory, follow the configuration rules below.

- DIMMs must be identical.
- Install two DIMMs per CPU at a time.
- Maintain an equal amount of memory for each CPU.
- Use a minimum of two matched DIMMs per CPU.
- Do not mix DIMM capacities.

To Remove Memory

1. Turn server power off.

2. Remove the service panel.

3. Locate the correct DIMM socket.

4. Press down on the retention latches at the sides of the memory module.
 - This frees the module from its socket

5. Remove the memory module.

To Add Memory

1. Turn server power off.

2. Remove the service panel.

3. Locate the correct DIMM socket.

4. Open the retaining clips.

5. Press the memory module into the DIMM socket.

6. Apply even pressure to the top edge of the memory module until it clips into place and the retention latches close to secure it.

7. Replace the service panel.


OBTAIN CUSTOMER ACCEPTANCE
   WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

Restart software applications per applicable administration guides to resume system operation.