![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1488323.1 : How to Remove and Replace Sun Blade 2500 Silver Memory Fan:ATR:1488323.1:0
In this Document
Applies to:Sun Blade 2500 Silver (1.6 Ghz) Workstation - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalThis document provides the procedure on how to Remove and Replace a Sun Blade 2500 Memory Fan Solution
DISPATCH INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTIONS ARE REQUIRED: Removing the DIMM Fan Assembly
3.Press the green tab of the hard drive assembly and gently slide the hard drive assembly to the left. Caution – The 6-pin power supply, 4-pin SCSI to optical drive power cable, and SCSI interface cable are still connected to the hard drive assembly. Be careful not to pull on them. 4.Place the hard drive assembly in a secure location on the chassis. 5.Disconnect the following cables from the interposer board on the DIMM fan assembly: 6.Using the No. 2 Phillips screwdriver, loosen the screw that secures the DIMM fan assembly to the motherboard. 7.Press the two latches, then lift and remove the DIMM fan assembly. The Sun Blade 2500 system does not operate without the DIMM fan assembly installed.
Installing the DIMM Fan Assembly
1.Locate where the DIMM fan assembly is to be installed. 2.Remove the new DIMM fan assembly from its packaging. 3.Position the DIMM fan assembly over the DIMMs and lower it to the motherboard. 4.Attach the two latches to the underside of the motherboard. Caution – Do not overtighten the screw. Overtightening the screw will void the warranty. 6.Reconnect the following cables to the interposer board on the DIMM fan assembly 7.Reinstall the hard drive assembly. 8.Using a No. 2 Phillips screwdriver, attach the two screws. 9.Inspect the DIMM fan assembly to verify that: The two latches are secure to the motherboard, the screw is secure and not binding and cabling 10.Reposition the chassis. 11.Install the access panel, power on the system, and verify the component installation.
WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://support.oracle.com/handbook_private/Systems/SunBlade2500S/components.html#Fan
ADDITIONAL COMMENTS: Sun Blade 2500 Service, Diagnostics, and Troubleshooting Manual (Silver): http://docs.oracle.com/cd/E19127-01/blade2500.ws/817-5117-11/817-5117-11.pdf Attachments This solution has no attachment |
||||||||||||||
|