Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1487935.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1487935.1 :   How to Remove and Replace Sun Blade 2500 Silver SCSI Disk Drive Backplane Fan Assembly:ATR:1487935.1:1  


Related Items
  • Sun Blade 2500 Silver (1.6 Ghz) Workstation
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: it is a FRU part

Applies to:

Sun Blade 2500 Silver (1.6 Ghz) Workstation - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

   Sun Blade 2500, How to Remove and Replace SCSI Disk Drive Backplane Fan Assembly

Solution

 

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Sun Blade 2500 product training is desirable but not required

TASK COMPLEXITY: 1

TIME ESTIMATE: 45 minutes

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW: SCSI Disk Drive Backplane Fan Assembly failure

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE:

Removing the Hard Drive Fan

1.Power off the system and open the chassis.

2.Locate the hard drive fan.

3.Remove the PCI card support and the chassis cross brace.

4.Disconnect the hard drive fan cable from power supply connector P7.
The cable might be connected to P8 or P9.

5.Using a No. 2 Phillips screwdriver, remove the four screws that mount the hard drive fan to the hard drive bracket.

6.Remove the grille and fan from the standoffs of the hard drive bracket and set them aside.

Note – Operating the Sun Blade 2500 workstation without the hard drive fan is not advised.

Installing the Hard Drive Fan

1.Locate where to install the new hard drive fan.

2.Remove the fan from its packaging.
Note – Molded into the body of the fan are two arrows. One arrow points the airflow direction, the other arrow points the fan rotation.

3.Align the fan under the standoffs with the cable towards the power supply and the airflow arrow on the body of the fan pointing up.

4.Insert one screw through the grille and into one corner of the fan.

5.Thread the screw into the standoff enough to bear the weight of the fan.

6.Thread the remaining three screws through the grille, through the fan corners, and into the respective standoffs.

7.Using the No. 2 Phillips screwdriver, tighten the four screws.

8.Connect the hard drive fan cable to power supply connector P7.
If P7 is not available, use P8 or P9.

9.Install the PCI card support and chassis cross brace.

10.Install the access panel, power on the system, and verify the component installation.

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.


PARTS NOTE: Include SCSI Disk Drive Backplane Fan Assembly location:

https://support.oracle.com/handbook_private/Systems/SunBlade2500S/components.html#Fan

 

 

ADDITIONAL COMMENTS:

Please refer to the:

Sun Blade 2500 Service, Diagnostics, and Troubleshooting Manual (Silver): http://docs.oracle.com/cd/E19127-01/blade2500.ws/817-5117-11/817-5117-11.pdf